21
The hose and regulator are connected in the following
manner:
Slide back the collar of the quick disconnect on the tank
valve. Push the male fitting of the regulator into the
quick disconnect, and maintain pressure. Slide the collar
closed. Figure 26 (a). Figure 26 (b) shows the quick
disconnect engaged and various components of the
tank and regulator. Regulator vent hole should be at
3, 6, or 9 o'clock. It should not be pointed up.
Figure 26 (c).
Figure 26
Turn so regulator vent
does not collect water
Hose
Tank lock
wing nut
Quick disconnect
engaged
Valve handwheel
close clockwise
Tank valve
Collar
Male
fitting
Pressure
relief valve
Tank
Regulator
Regulator
vent
(a)
(b)
(c)
Step 18
Connect LP tank
You will need: hose clamp and 1/4-20 x5/8 screw,
regular screwdriver.
WARNING: Make sure that the LP tank valve is
closed. Close by turning clockwise.
Hook the LP tank onto the fuel scale. Loosen the tank
lock wing nut. Swing the tank lock down. Tighten the
wing nut. Figure 24.
Figure 24
Figure 25
F
E
Put the clamp over the hose. Insert the screw through
the hose clamp and into the threaded hole in the side of
the wheel frame leg. Tighten. Figure 25.
WARNING: Hose must be in front of the wheel
frame leg.
WARNING: Make sure that the hose cannot come
in contact with the cooking box assembly.
a)
Hose
Hose
clamp
Hole in side
of wheel
frame leg