Parameters:  

 

interface

:  the  interface  to  use  for  the  detection.  The  interfaces  must  have  been 

configured first. The possible values are: 

o

 

serial1

: detection on serial port 1 

o

 

serial2

: detection on serial port 2 

o

 

serial3

: detection on serial port 3 

o

 

ethernet1

: detection on the ethernet 1 port 

o

 

ethernet2

: detection on the ethernet 2 port 

 

max devices

: optional. Maximum number of devices to detect. If this parameter is left 

out,  the  detection  continues  until  the  end  of  all  possible  searches.  Otherwise  the 
detection stops as soon as a sufficient number of devices have been detected on the 
interface. 

Responses: 

 

When the detection completes successfully, the following message is returned: 

SunSpec detection finished in <counter> seconds. 
<devices> detected and added. 

The detection completed successfully in “counter” seconds. “devices” indicates the number 

of detected devices. 

 

If a detection is running and a new detection is requested, the following message is 
returned: 

SunSpec detection already in progress. 

 

The detected errors will be the following: 

 

The indicated interface is not valid for SunSpec detections: 

Invalid detection interface 

 

 

The number of parameters is invalid: 

Invalid detection parameters 

 

3.3.7

 

“factory” reset command

 

The 

“factory” command is used to reinitialise the concentrator. The configuration files and the 

device acquisition data are deleted and the product is rebooted immediately. 

Syntax: 

Содержание WebdynSunPM

Страница 1: ...WebdynSunPM Supervision gateway for photovoltaic installations USER MANUAL...

Страница 2: ...all mounting 21 Interface description 22 2 4 1 Product power supply 22 2 4 1 1 External power supply 22 2 4 1 2 Battery 23 2 4 2 Cellular Network 23 2 4 2 1 Antenna 23 2 4 2 2 SIM card 24 2 4 3 Indica...

Страница 3: ...ing a device 85 3 2 1 2 4 Modifying the input output configuration 86 3 2 1 2 5 Duplicating a device 89 3 2 2 Settings 90 3 2 2 1 Concentrator 90 3 2 2 2 Serial 91 3 2 2 3 Networks 93 3 2 2 4 Modem 95...

Страница 4: ...6 4 1 5 CMD commands 138 4 1 6 SCRIPTS 138 4 1 7 BIN update 138 4 1 8 LOG 139 4 1 8 1 Connection logs 139 4 1 8 2 Script logs 142 4 1 8 3 SunSpec detection logs 142 4 1 8 4 System logs 144 The MQTT MQ...

Страница 5: ...d values Open text format representing tabulated data in the form of values separated by semi colons This format makes it easy to use data with spreadsheet software such as Excel DNS Domain Name Syste...

Страница 6: ...strial control equipment in Europe RSSI Received Signal Strength Indication Reception power level measurement of a signal issued by a radio antenna RTU RTU mode is an RS422 485 hard wired bus for Modb...

Страница 7: ...uting TIC Customer remote information Digital data output from ERDF meters that permanently broadcasts the managed contractual parameters as well as the consumption magnitudes measured by the meter UD...

Страница 8: ...stics Section 6 FAQ Scope This technical description is valid for WebdynSunPM concentrators as from hardware version V1 and software version V3 0 0 Target group This guide is intended for all people i...

Страница 9: ...9 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 1 Presentation...

Страница 10: ...principle The WebdynSunPM concentrator can be fully integrated into photovoltaic installations Devices such as inverters sensors pyranometers temperature sensors etc meters displays circuit breakers...

Страница 11: ...The interfaces Devices WebdynSunPM Operation 0 1 5 3 0 Sensors Meters Inverters Displays Circuit breakers Relays etc Web Server Scripts Data management Troubleshooting Text message Server MQTT Server...

Страница 12: ...g inputs 1 Relay output Indicators Power 12 24 V power supply status Activity Product status Serial1 Serial2 Serial3 Tx Data sent on the RS485 RS422 serial port Rx Data received on the RS485 RS422 ser...

Страница 13: ...cal interface Specifications SMA net RS485 RS422 2 wires 100 max Modbus TCP Ethernet 254 max Modbus RTU RS485 RS422 2 wires or 4 wires 247 max Power One Aurora RS485 RS422 2 wires 100 max TIC USB cabl...

Страница 14: ...F inputs AC1301 01 Single phase electricity meter AC1301 02 Single phase electricity meter with relay AC1302 01 Three phase electricity meter AC1302 02 Three phase electricity meter with relay AC1001...

Страница 15: ...he waste must be collected via a specific channel and must not be disposed of as household waste Symbol indicating that the product must be recycled 1 6 2 Technical specifications Specifications Descr...

Страница 16: ...S 1 6 3 Software specifications Specifications Protocols Formats Embedded server HTTP Server communication protocol IS FTP SFTP MQTT MQTTS generic and compatible with AWS IoT Azure IoT and Google Clou...

Страница 17: ...to gently clean and wipe the surfaces Never use aggressive chemical agents or solvents that could alter the plastic material or corrode the metal parts It is essential to leave a 20 cm empty space ar...

Страница 18: ...18 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 2 Installation and Maintenance...

Страница 19: ...d below for any intervention on site and to install the product To have a SIM card with an activated M2M subscription data and text messages optional and knowledge of the supplier s APN The SIM card c...

Страница 20: ...s accessible on the top of the product The product CE label on the back of the box Commercial reference Product serial number Date of manufacture WG0517 A01 WW Y Y MAC 00 05 F3 00 00 00 WFFVVAAHHHHHH...

Страница 21: ...oftware version is available on the Home tab See section3 2 Embedded web interface Assembly 2 3 1 Opening closing the box Users must not open the product It must be returned to after sales for all wor...

Страница 22: ...Pivot the concentrator downwards Before fixing or removing the concentrator make sure To cut the power supply to the equipment Remove the antenna taped to the back of the box Interface description 2 4...

Страница 23: ...lure fault and switch the product to safety mode until the power supply returns The battery recharges on the concentrator s external power supply The battery may not have time to recharge if the conce...

Страница 24: ...rs must make sure their installation using remote antennas meets applicable EMC standards 2 4 2 2 SIM card To use the 2G or 3G modem connection and allow the concentrator to communicate with the remot...

Страница 25: ...ition To remove the SIM card from the concentrator briefly press the end of the SIM card protruding from the product until it clicks then release it You can then recover the SIM card Webdyn does not s...

Страница 26: ...been shut down it can be rebooted by simply pressing the Power button 2 4 3 2 Factory Reset button The Factory Reset button is used to recover the product in any situation loss of IP address loss of...

Страница 27: ...efault operation During a long press on the Power button the Activity indicator will flash every second to help the user complete an action 2 4 3 5 Serial LED The bus has 3 RS485 422 serial buses and...

Страница 28: ...es followed by a 1 second pause Indicates the modem signal level by flashing 1 Unstable 2 Limit 3 Correct 4 Good 5 Excellent green Fast flashing FTP connection in progress orange Slow flashing NTP syn...

Страница 29: ...These Ethernet interfaces allow the concentrator to be part of 2 different Ethernet networks to communicate with local IP devices belonging to 2 separate networks or to communicate with the IS using...

Страница 30: ...interface The WebdynSunPM concentrator has 3 RS485 RS422 serial ports marked Serial on the bottom of the product which are only used for modbus in RTU mode This interface is Half Duplex 2 wires and Fu...

Страница 31: ...ned or shielded twisted pair per pair see above cable type for RS485 bus connection The cable screen or shielding must be connected to the concentrator box earth and not to the 0 V only connect one en...

Страница 32: ...carries data sent from the concentrator to the device and the other pair the data sent from the device to the concentrator Several systems can be connected to the bus as shown on the following figure...

Страница 33: ...m is balanced If the common conductor is not installed between all the devices they must be properly grounded in compliance with the manufacturer recommendations for each network device This requireme...

Страница 34: ...put is equal to the concentrator s power supply voltage The earth on each analog terminal block is common Each analog input can be software configured to 0 10V or 4 20mA The concentrators analog digit...

Страница 35: ...he sensors must not exceed 7 watts 2 4 7 2 Digital ON OFF S0 pulsed inputs The WebdynSunPM concentrator has 3 inputs that can be configured to ON OFF mode or S0 pulsed mode pulse counting These inputs...

Страница 36: ...onto the digital inputs In ON OFF mode The concentrator can detect dry contact openings and closures to report device status or trigger status change alarms ON OFF inputs Digital inputs Type Collector...

Страница 37: ...hing threshold disabled 8 mA 1 mA HIGH Switching threshold enabled 15 mA 2 5 mA Power supply voltage Internal 24 V Internal 5 V Pulse counters 20ms 20ms Meters with class A pulse outputs should be use...

Страница 38: ...nSunPM Version 2 05 pr liminaire This output has the following specifications Specifications MAX values Voltage 24 V Current 1A The relay output can be controlled using LUA scripts See section3 2 3 1...

Страница 39: ...39 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 3 Configuration...

Страница 40: ...he equipment pool If the local web interface and the FTP files are modified at the same time the FTP files take precedence Any modifications to files on the FTP server will overwrite any possible loca...

Страница 41: ...uration file Description PIN code pin The SIM card PIN code to be entered if it has one APN apn Your mobile operator s APN name required for an IP connection Authentification type authentication Opera...

Страница 42: ...which can be PIN code status Description PIN code OK The modem can access the SIM card Either the SIM card PIN code is correct or the SIM card has no PIN code PIN code Required The SIM card expects a...

Страница 43: ...dem of 0 to 31 dBm Signal level returned by the modem interpreted in dBm of 113 to 51 IP Address IP address assigned automatically by the mobile operator DNS Address DNS address assigned automatically...

Страница 44: ...tion file retrieval on the FTP server They are never a substitute for full FTP or web configuration FTP SFTP As indicated previously this configuration method takes precedence over local configuration...

Страница 45: ...DEF directory on the FTP server Please note that the concentrator does not create a configured tree structure Therefore all the configured directories need to be created manually Thus by default the...

Страница 46: ...ion uid _scl ini this file contains the configuration parameters for the scripts installed on the concentrator uid _var ini this file contains the concentrator connection scheduling configuration para...

Страница 47: ...e 3 1 2 1 2 uid _var ini file The _var ini file contains the scheduling list configured on the concentrator The file name is defined as follows Take the device uid as explained previously and suffix _...

Страница 48: ...sday the schedule will be run every Wednesday thursday the schedule will be run every Thursday friday the schedule will be run every Friday saturday the schedule will be run every Saturday sunday the...

Страница 49: ...arams 0 1 everyday 00 00 00 1440 1 SCHEDULE2_Params 1 2 everyday 00 00 00 1440 1 SCHEDULE2_Params 2 3 everyday 00 00 00 86400 1 The index number is calculated automatically by the concentrator startin...

Страница 50: ...nnected device configuration 3 1 2 1 3 1 Modem configuration Modem configuration is based on the following parameters Parameter Description Default value Type Device type The only possible value here...

Страница 51: ...or Always make sure to indicate the delimiter format when saving 3 1 2 1 3 2 Ethernet connection configuration Ethernet interface configuration is based on the following parameters Parameter Descripti...

Страница 52: ...mpty Ethernet interframe configuration The interframe time for serial ports is given directly in the configuration for each serial port For Ethernet devices it is more complicated to determine the com...

Страница 53: ...guration is based on the following parameters Parameter Description Default value Type Device type The possible values are SERIAL1 to configure the Serial 1 interface SERIAL2 to configure the Serial 2...

Страница 54: ...U InterFrame The waiting time between 2 frames exchanges on the serial port This time is expressed in ms See below for a detailed explanation of how this parameter operates 0 Forwarded TCP port Forwar...

Страница 55: ...9600 bauds 8 data bits no parity 1 stop bit 2 communication wires modbus protocol and no inter frame time The 2nd serial port is configured at 1200 bauds 4 wires to be used with the SMA Net protocol T...

Страница 56: ...SERIAL2 the device is connected to serial port 2 SERIAL3 the device is connected to serial port 3 IP address the device is of the modbus TCP type and is accessible at the indicated IP address IP addr...

Страница 57: ...tor fills in this field automatically For TIC devices the field is left empty and will be used in the future Model This field indicates the device model name Note that the concentrator fills in this f...

Страница 58: ...tes that the device is of the TIC type o Interface empty As TIC devices use external interfacing equipment supplied by Webdyn this field is ignored o Name tic The name that will be displayed on the lo...

Страница 59: ...erter_9301_modbusTCP csv The definition file name that describes the different variables configured for this device detected using SunSpec When editing this file using Excel the following display is s...

Страница 60: ...SCRIPT_File 1 Test script 2 lua The index number is calculated automatically by the concentrator starting with 0 If this file is modified manually make sure there are no duplicate index numbers as thi...

Страница 61: ...ccepted Files generated automatically or created by the local web interface will be named as follows 3 1 2 2 1 1 TIC The TIC file names are defined as follows File name Description uid _TIC_CBEMM csv...

Страница 62: ...o modbusTCP for modbus devices on Ethernet 3 1 2 2 1 4 SMA The SMA file names are defined as follows uid _SMA_ Model csv Model is generated automatically from the SMA Net protocol Model information 3...

Страница 63: ...lation of totals issuing of commands to multiple devices etc This name must be unique to allow unambiguous identification and use in the scripts CoefA Contains the multiplier to apply to the variable...

Страница 64: ...protocol and are therefore configured as follows 3 1 2 2 2 1 TIC Field Description Info1 This field will be used to indicate the variable description This is the name of the variable to be collected...

Страница 65: ...er strings for example The format is the following Register address_Size Thus for example the value 40000 10 configures a variable of which the data is at register 40000 and is 10 bytes long Register...

Страница 66: ...n at byte level one by one _WB the words AND the bytes are exchanged The 2 previous modifiers are applied Thus for example the I32_W notation indicates that it is a variable of which bytes 1 and 2 wil...

Страница 67: ...ate 2 frames and will not attempt to group the 2 variables together in a single request 3 1 2 2 2 4 SMA Field Description Info1 Channel The channel number for the variable to be collected This informa...

Страница 68: ...face To access the concentrator s embedded web interface follow the steps below 1 Launch the web browser The web interface is compatible with the latest browser versions Firefox Chrome and Edge Older...

Страница 69: ...rator we recommend changing the default passwords following the first configuration Passwords are modified using the web interface see section 3 2 2 7 Password or using the configuration file see sect...

Страница 70: ...following SunSpec The modbus devices in the tables meeting the SunSpec standard specification http www sunspec org can be detected and configured automatically using the Ethernet modbus TCP or serial...

Страница 71: ...time By leaving the default value 254 all the devices will be polled and all detectable devices will be detected o Select the interface to use for detection in the Interface field If the device respon...

Страница 72: ...56 10 NON SUNSPEC device found at 1 192 93 121 23 502 This means that a modbus device that does not meet SunSpec specifications was found at IP address 192 93 121 23 with modbus address 1 o SunSpec de...

Страница 73: ...play result button appears and gives access to the last page The last detection page is used to view all detected devices and eventually to add them to the configuration This screen therefore displays...

Страница 74: ...the previous device is not overwritten A new device is created in addition to the pre existing device 3 2 1 1 2 TIC device detection The automatic detection of TIC devices requires the following step...

Страница 75: ...the drop down list on the first Protocol field o The other fields will disappear and only TIC 1 will be displayed in the Interface field This field is read only Then click the Start detection button...

Страница 76: ...ed It is always possible to interrupt detection by clicking the Abort detection button On completion of the detection the TIC device is imported into the concentrator configuration automatically 3 2 1...

Страница 77: ...Net protocol from the drop down list on the first Protocol field o Enter the maximum number of devices to detect in the Max devices field This can speed up the total detection time By leaving the defa...

Страница 78: ...A Net scan has begun o As the detection progresses the screen displays the detected devices with their index serial number model and address on the bus Device idx 0 serial 2000388220 model WR21TL09 Ad...

Страница 79: ...ht to select the devices to add to the configuration Note that if the detected device is already part of the configuration the checkbox is not checked by default Otherwise the checkbox is checked for...

Страница 80: ...ew import the previous device is not overwritten A new device is created in addition to the pre existing device Manual device management Devices can be managed manually on the web site Everything is m...

Страница 81: ...to find the corresponding definition file This information cannot be entered directly It is obtained using the internal device definition file database If the required device is not found in the drop...

Страница 82: ...ck the Open button Finally click the import button to complete the definition file import A Done message is displayed on the web interface to indicate the operation was successful Once the definition...

Страница 83: ...y 502 Slave address the device s modbus address When the device is of the modbus RTU type the following fields are displayed Serial port the serial port to which the modbus slave is connected RTU Slav...

Страница 84: ...84 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 3 2 1 2 2 Deleting a device To delete a device first select the device to delete Then click the trash icon under the device description...

Страница 85: ...moved from the concentrator databases The modification will be carried over to the configuration files at the next server connection 3 2 1 2 3 Editing a device To edit a device first select the device...

Страница 86: ...be modified by importing a new definition file To do that just click the Import Def File button and select the new definition file as indicated in section 3 1 2 1 3 4 Connected device configuration On...

Страница 87: ...ebdynSunPM Version 2 05 pr liminaire The first part of the screen is used to configure the 3 digital inputs The fields are Field Description Type Digital input type The authorised values are Dry Loop...

Страница 88: ...an alarm is triggered The data read at collection time will be stored in the data file using a single field Contact Indicates the normal status of this input namely its standby state The possible val...

Страница 89: ...er to apply to the input so that it complies with the unit described in the unit field This multiplier is a floating point number using a decimal point This factor is there to inform users and is not...

Страница 90: ...It then becomes possible to rename and change the definition file by editing the device see section 3 2 1 2 3 Editing a device 3 2 2 Settings All the concentrator settings are grouped together on the...

Страница 91: ...ss indicated on the product label see section 2 2 2 Identification Identifier The identifier is used when creating the names of the files uploaded to the server It is important that it be unique to be...

Страница 92: ...ort configured in modbus RTU mode SMANET serial port configured for the SMA Net protocol PW1 serial port configured for the PowerOne protocol Mode wires Serial interface mode RS485 2 wires Half Duplex...

Страница 93: ...s field the concentrator opens a modbusTCP port on the entered port number When modbusTCP devices connect to this port all sent requests are directly forwarded to the modbusRTU bus and the response is...

Страница 94: ...thernet network subnet mask This mask limits the Ethernet network to defined IP addresses and separates the network ranges from each other Gateway gateway Your Ethernet network gateway address The gat...

Страница 95: ...ss You can also use the google DNS 8 8 8 8 DNS 2 dns2 DNS 2 server If the DNS1 server fails If your local network is managed by a network administrator contact them before including the WebdynSunPM ga...

Страница 96: ...uration file Description PIN code pin The SIM card PIN code to be entered if it has one APN apn Your mobile operator s APN name required for an IP connection Authentification type authentication Opera...

Страница 97: ...which can be PIN code status Description PIN code OK The modem can access the SIM card Either the SIM card PIN code is correct or the SIM card has no PIN code PIN code Required The SIM card expects a...

Страница 98: ...dem of 0 to 31 dBm Signal level returned by the modem interpreted in dBm of 113 to 51 IP Address IP address assigned automatically by the mobile operator DNS Address DNS address assigned automatically...

Страница 99: ...f authentication is required the login and or password are incorrect As long as the problem persists the concentrator will not be able to use the modem to connect to the remote server On the other han...

Страница 100: ...ort FTP SFTP server port Login FTP_Login FTP2_Login User name used by the concentrator for the connection to the remote FTP SFTP server Password FTP_Password FTP2_Password Password used by the concent...

Страница 101: ...sation Unchecked No certificate synchronisation Data file header option enabled FTP_HeaderOption FTP2_HeaderOption Optional header selection in the data files uploaded to the FTP SFTP server Checked W...

Страница 102: ...log is displayed showing all the files exchanged between the concentrator and the remote server Looking at the last line is a quick way to see if the connection was successful or not The ending of an...

Страница 103: ...hedule will be run every Sunday First day of each month the schedule will be run on the 1st of every month 15th of each month the schedule will be run on the 15th of every month Last day of each month...

Страница 104: ...rvals you can enter a value of more than 1440 in Count Example 1 For a regular file upload every hour the schedule should be configured as follows Example 2 For a regular file upload every Sunday at m...

Страница 105: ...which are then uploaded to the remote server by the concentrator For example if you select the GMT 01 00 Europe Brussels Copenhagen Madrid Paris time zone the concentrator will indicate The date and...

Страница 106: ...lo GMT 02 00 Brazil GMT 01 00 Azores UTC GMT 01 00 Europe Brussels Copenhagen Madrid Paris GMT 01 00 Algiers GMT 02 00 Athens Bucharest Istanbul GMT 02 00 Cairo GMT 03 00 Moscow St Petersburg Volgogra...

Страница 107: ...T 11 00 Magadan Solomon Islands GMT 13 00 Auckland Wellington The time differences for countries are not taken into account by the concentrator NTP The NTP settings are Web interface Parameter in the...

Страница 108: ...rver This server does not guarantee the exactness of the time synchronisation nor its robustness The use of a specific NTP server is strongly recommended Contact an NTP server portal or supplier After...

Страница 109: ...ible to re display the last connection log by clicking the Magnifier button The concentrator time can be synchronised with the PC time by clicking the Set time from PC button The time zone configured...

Страница 110: ...the default passwords following the first configuration The password can also be changed using the WEB_Password variable in the config file uid _config ini If you lose the password and no servers are...

Страница 111: ...WebdynSunPM LUA User Guide pdf Script configuration and management are accessed from the local web site page This page can be used to import new scripts enable them disable them or even delete them o...

Страница 112: ...cript will appear in the script management window Note that the scripts are imported stopped this means they are not started automatically The information displayed on the web page comes from the scri...

Страница 113: ...of what can be done Disabling a script meets stopping it from running Note that scripts are run automatically when the WebdynSunPM concentrator starts up even if they were disabled before the start u...

Страница 114: ...utton displays the following page The page is closed by pressing the cross at the top right indicated above in the circle 3 2 3 1 4 Viewing the script It is possible to display the source code for the...

Страница 115: ...g a script Pressing the script export button launches an immediate local script load by the browser When the user clicks this button the script is loaded directly into the browser downloads directory...

Страница 116: ...update the the concentrator 1 Retrieve the firmware from the web site see section 5 Update https www webdyn com support webdynsunpm 2 Unzip the retrieved file 3 Click the Select your firmware file fie...

Страница 117: ...the concentrator s Upgrade page 11 Check that the new version is shown in the Firmware version field The concentrator has been updated Do not disconnect the concentrator and avoid operations on it du...

Страница 118: ...ns the browser page needs to be refreshed using the F5 function for example to be able to log back in Text message command Commands can be sent to the WebdynSunPM concentrator modem by text message Be...

Страница 119: ...command The ftp command is used to configure the Server 1 FTP server Syntax ftp server login password port interface Parameters server the name of the FTP server to connect to This parameter can be a...

Страница 120: ...e the concentrator identifier uid firmware version the version of firmware currently loaded on the concentrator 2 6 eth0 ip ipaddr mask mask gw gateway dns dns ipaddr IP address configured on the eth...

Страница 121: ...status status type type mode mode addr ipaddr port port last server configured server 1 name status indicates whether server 1 is enabled or not The possible values are o enabled server 1 is enabled o...

Страница 122: ...er 2 is of the MQTTS type mode the server 2 running mode The possible values are o strategy_wsun1_compliant_backup the server is an FTP type server and is configured as a backup server o strategy_wsun...

Страница 123: ...en detected on the interface Responses When the detection completes successfully the following message is returned SunSpec detection finished in counter seconds devices detected and added The detectio...

Страница 124: ...124 USER MANUAL WebdynSunPM Version 2 05 pr liminaire factory Parameters none...

Страница 125: ...125 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 4 Operation...

Страница 126: ...s must be uploaded to the server in an INBOX directory associated with the concentrator Monitor the concentrator and assist in diagnosis The concentrator can upload log files for diagnosis purposes If...

Страница 127: ...ry the FTP server must have the following directories Name Rights Description CONFIG Read Write Contains the configuration files The concentrator configuration uploaded by the concentrator is in the f...

Страница 128: ...r interface the interface name from a defined list see section 3 1 2 2 2 Definition file content comment free user field version update version number The data alarm and log files are compressed to th...

Страница 129: ...mmand file Alarm file Delimited data file in the form of semi colon delimited values easy to use with Excel type spreadsheet software lua Script file Lua language script pem Certificate file PEM forma...

Страница 130: ...the new configuration has been applied the result is indicated in the concentrator s log file If there is an error in the configuration file such as an incorrect value the concentrator will not take...

Страница 131: ...it has the following format uid _ interface _ comment csv Where uid Concentrator identifier interface the interface name from a defined list see section 3 1 2 2 2 Definition file content comment free...

Страница 132: ...ator can store up to 50Mb of uncompressed data per defined device The WebdynSunPM permanently collects the device and interface data and saves it The reported values are always raw and must be connect...

Страница 133: ...rmatting is identical regardless of the device or interface The reported values are raw and must be linked to the configuration on the device or the interface in its definition file The IS must interp...

Страница 134: ...g data to the server and thereby optimise the connection it is recommended to only enable the variables that need to be reported TIC The webdynSunPM permanently collects the data from the TIC flow and...

Страница 135: ...Input Output IO Example of an IO data file with an acquisition frequency of every 10 seconds Input output configuration Input Output Action code Display 1 4 Instant value 2 0 None 3 4 Instant value 4...

Страница 136: ...avg 21 02 05 09 50 00 16 32 26 00 52 58 51 00 21 02 05 10 00 00 4 6 05 50 102 105 103 00 4 1 4 ALARM alarms Alarms are uploaded in the form of CSV format files compressed to Gzip gz format They are up...

Страница 137: ...5 Servers info_X Information on alarm X The IO and MODBUS type alarm file format is the following Colour code Blue Device specific information or data Where datetime_Y alarm timestamp at trigger poin...

Страница 138: ...7 00 49 MODBUS MODBUS_DELTA_M88H COM1 20 Sunspec csv OndA 48 3 000000 4 1 5 CMD commands Future upgrade 4 1 6 SCRIPTS The SCRIPT directory on the FTP server is used to supply or retrieve Lua scripts t...

Страница 139: ...logs uid _SYSTEM_ date log gz 4 1 8 1 Connection logs Every time the concentrator connects to a server either by modem or Ethernet all operations are saved for future viewing When the connection is f...

Страница 140: ...king Test script 2 lua 2021 02 11 14 25 21 No change 2021 02 11 14 25 21 Configuration file summary 2021 02 11 14 25 21 WPM00BDE4_SunSpec_inverter_SMA_Solar_Inverter_9301_modbusTCP csv Action Get remo...

Страница 141: ...g remote changes Modifications were also detected on the devices and the _daq csv file is sent to the FTP server 2021 02 11 14 25 21 Local changes sent WPM00BDE4_daq csv The processing completes with...

Страница 142: ...n The log file can be viewed in 2 ways Either directly on the local web site on the script page by clicking the view log icon see section 3 2 3 1 Scripts Or on the FTP server in the log files The logs...

Страница 143: ...0087 126 192 93 121 23 502 21 02 11 17 27 51 Found table 101 50 at 40187 126 192 93 121 23 502 21 02 11 17 27 52 Found table 120 26 at 40239 126 192 93 121 23 502 21 02 11 17 27 53 Found table 121 30...

Страница 144: ...on must be enabled on the server configuration page The system log files are also transferred automatically when a connection is forced from the server configuration page by clicking the Connect butto...

Страница 145: ...145 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 5 Update...

Страница 146: ...ning the updates in the BIN directory on the remote server 2 Edit the uid _config_ ini file uid Concentrator identifier which is in the CONFIG directory on the FTP server Put the file name that has ju...

Страница 147: ...147 USER MANUAL WebdynSunPM Version 2 05 pr liminaire...

Страница 148: ...148 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 6 Tools diagnostics...

Страница 149: ...trator function in order to better isolate problems If necessary the concentrator can also be rebooted remotely using the reboot text message command see section 3 3 4 reboot command The product can a...

Страница 150: ...150 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 7 Support...

Страница 151: ...78100 Saint Germain en Laye Phone 33 1 39 04 29 40 Email support webdyn com https www webdyn com Please have the following elements to hand Product type Product serial number Product hardware and sof...

Страница 152: ...152 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 8 FAQ...

Страница 153: ...i etc and enter the WebdynSunPM concentrator IP address in the address bar An authentication page is displayed The default accesses are Login Password userhigh high Click Login How do you configure th...

Страница 154: ...on the configuration must be compatible with the concentrator s local network topology so that it can access the servers This configuration is done from the Networks configuration page see section 3 2...

Страница 155: ...entration configuration see section 3 3 3 ftp FTP configuration command ftp server login password port interface o Connect to launch the connection to the FTP server and load the configuration see sec...

Страница 156: ...number see section 3 3 7 factory reset command The factory reset restores the original configuration The data is not kept Can the gateway send commands to connected devices It is possible to send comm...

Страница 157: ...ion 1 4 Supported devices Modbus device compatibility Can I connect different Modbus devices to the same serial port Yes different Modbus devices can be connected to the same serial port Device compat...

Страница 158: ...ti tariff blue meter CBEMM Single phased electronic multi tariff blue meter CBEMM ICC evolution Three phased electronic multi tariff blue meter CBETM Electronic yellow meter CJE Interface Client le Em...

Страница 159: ...159 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 9 APPENDICES...

Страница 160: ...ate configuration for how to use updates 3 1 2 1 Concentrator_Identifier Gateway identifier uid If this field is left empty the default identifier is used WPMABCDEF where ABCDEF are the last character...

Страница 161: ...2 Concentrator operation CONFIG FTP_DirData FTP 1 server directory to which the concentrator uploads the data files collected during operation Note that the directory MUST exist The concentrator will...

Страница 162: ...on to the FTP 1 server is kept alive This value is expressed in seconds A value of 0 indicates that the connection is ended as soon as processing completes 0 FTP_EuroDateFormat Indicates the format us...

Страница 163: ...d Note that the directory MUST exist The concentrator will not create it when uploading files ALARM FTP2_DirBin FTP 2 server directory in which the concentrator will get the update files when requeste...

Страница 164: ...ate it when uploading files See the section on definition file configuration for the operating principle see section 3 1 2 2 Connected device definition DEF FTP2_DirLog FTP 2 server directory to which...

Страница 165: ...connect to server FTP 2 FTP2_Port The network port to use to connect to the FTP 2 server 21 FTP2_SynchroniseCertificates Future upgrade 0 FTP2_TwoStepsSendingDisabled Used for file transfers in 2 ste...

Страница 166: ...The possible values are ethernet uses the ethernet connection modem uses the 3G interface with the embedded SIM card This parameter cannot be empty ethernet SERVER_Type The type of server to which the...

Страница 167: ...rver type The possible values are ftp FTP server sftp SFTP server mqtt MQTT server mqtts secure MQTT server mqtts_aws MQTTS server on AWS IoT mqtts_gcloud MQTTS server on Google Cloud IoT This paramet...

Страница 168: ...03 00 Antarctica GMT 03 00 Sao Paulo GMT 02 00 Brazil GMT 01 00 Azores UTC GMT 01 00 Europe Brussels Copenhagen Madrid Paris GMT 01 00 Algiers GMT 02 00 Athens Bucharest Istanbul GMT 02 00 Cairo GMT...

Отзывы: