Legend for circuit diagrams
Air Top Evo 3900 / Air Top Evo 5500
88
Item
Description
Comment
A1
Heater
Air Top Evo 3900/5500
A2
Control module
Control unit 1580
B2
Temperature sensor
Internal
B3
Overheating sensor
Overheating guard
B4
Temperature sensor
External
E
Glow plug / Flame monitor
F1
Fuse 15 A (24 V)
or 20 A (12 V)
Flat fuse SAE J 1284
F2
Fuse 4 A
Blade fuse SAE J 1284
not contained in wiring harness
F3
Fuse 1 A
Flat fuse SAE J 1284
F4
Fuse 4 A
Blade fuse SAE J 1284
not contained in wiring harness
F5
Fuse
Value in [A] to be selected depend-
ing on line cross-section
H1
LED green (in item S1)
Indicator
H2
LED red (in item P)
Light in immediate heat button,
ready indicator,
Switch-on indicator
H3
Heating symbol in the display
(in item P)
Indicator
H4
Light bulb/LED
(in item P and S)
Display and button lighting
H5
Light bulb/LED
Switch-on indicator pumping device
K
Relay
with free-wheeling diode
for vehicle fan
M1
Motor
Combustion and hot air fan
M3
Motor
Vehicle fan
P
Combination timer (1531)
Timer and setpoint generator
R
Resistor
In adapter wiring harness
R1
Resistor 620
Ω
With internal temperature sensor
only
S
Control Panel MC04/05
On/Off switch, setpoint generator
and selector switch for additional
functions
S1
Basic heater control
On/Off switch and setpoint genera-
tor
S2
Switch Ventilation
S3
Switch
CO
2
setting
S4
Push button
External instant heat button
S5
Switch
Pumping devices/
auxiliary drive
S6
Switch, single or two-pin
Isolation switch
S7
Battery isolation switch
Electronically controlled isolation
switch
S8
Switch
Boost (e.g. door contact on ambu-
lance)
X1-X7
Plug connector
on item A2
X8a
Plug connector
to item S3
X8b
Plug connector
Connection of additional heaters
via serial bus interface
X9a
Plug connector
on item S or S1
X9b
Plug connector
on item S or S2
X9c
Plug connector
W bus, optional connection of Tele-
start (12 V) or Thermo Call
X10-X12 Plug connector
X13
Plug connector
to item Y1
X14
Plug connector
to item P
X15
Plug connector
Connection of additional heaters
via serial bus interface
X16
Plug connector
W bus
X17-X18 Plug connector
Y1
Metering pump
Y2
Solenoid valve/pump
Pumping devices/
auxiliary drive
Item
Description
Comment
Installation_Instructions_Air_Top_Evo_3900_5500_de_en_nl.book Page 88 Wednesday, November 3, 2010 11:58 AM