4.
Technical Data
As long as no threshold values are given, the following
technical data are understood to include tolerances of
±
10% usual for heaters at an ambient temperature of
+20 °C and at nominal voltage and conditions.
Electrical Components:
Control unit, combustion air fan, dosing pump, timer*,
glow plug and control element are for 12 or 24 Volts
operation.
The components temperature limiter and flame detector
are independent of voltage.
*not for TRS
Permitted ambient temp.:
Heater:
Dosing pump:
Control element:
- operation
- storage
- operation
- storage
- operation
- storage
Air Heater
Operation
AT 2000 B
Mark of conformity
Heater type
Heat flow
Type of fuel
Fuel consumption
Nominal voltage
Operation voltage
Rated power consumption
Volume flow of heating air
against 0.5 bar
CO
2
in exhaust
(perm. functional range)
Dimensions air heater
Weight, heater
Control range
Air heater with
evaporator burner
1.1 – 2.0 kW
Fuel
0.1 .. 0.2 kg/h (0.16..0.27 l/h)
10 … 15 Volt
12 Volt
9 ...22 W
-40
°
… +40
°
C
-40
°
… +85
°
C
-40
°
… +20
°
C
-40
°
… +85
°
C
-40
°
… +75
°
C
-40
°
… +85
°
C
+10 ... +45
°
C
70 m
3
/h
9.5 … 10.5
Length 322
±
2 mm
Width 130
±
1 mm
Height 122
±
1 mm
2.6 kg
Control range
Max.
Max.
~ S 277
AT 2000 D
0.9 – 2.0 kW
Diesel/Fuel oil (EL)
0.1 .. 0.21 kg/h (0.12 .. 0.24 l/h)
20 … 30 Volt
12 Volt
9.5 … 12.0
~ S 270
Control range
24 Volt
10 … 15 Volt
Control range
Permitted combustion air
intake temperature
-40 ... +20
°
C
Setting range for
indoor temperature
401
Air Top 2000
4 Technical Data