background image

BASIC TASKS

TOUCHPAD

ACTIVATE

Access this controller from WeatherTRAK.net or 

WeatherTRAK Mobile

•  Call Customer Support at: 800.362.8774
•  Fill out the activation form at: hydropoint.com/activate

SET CONTROLLER MODE

Controller On/Off, Shutdown, or Winterized

•  Press 

 button 

•  Use      button to select desired function
•  To clear Shutdown or Winterized, press 
 

 Button, then press       to reset the status

ASSIGNING THE DECODER TO A STATION 

Note: 

For a dual valve decoder, the stations will 

be sequential.

1. Plug the decoder into the terminal located on the 

mini-chassis board (figure 1)

2. Press 

3. Press      until 

 displays 

(screen 15)

4. Press      or      until 

 displays 

5. Press 

6. Press     . The controller reads the decoder and 

assigns it to the next station in sequence. If you need 

to change the station number, press      or                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                      

7. Press      to assign the decoder to the station shown

8. Press      or      to set the power level. Power levels for 

each station can be adjusted independently. Note 

that the power level defaults to Low

9. Press      to configure the decoder 

10. Label the decoder then unplug it from the Station 

Program terminal

11. To assign the next decoder, press      . To exit 

ALERT MANAGEMENT

MOBILE APP

Go to the 

 

 tab on the Controller Settings page.

WEB

Use Alerts Page, or Multi-Controller Alert Report from 

weathertrak.net. 

CONTROLLER

While at the controller, use the following process:
Press 

 

 Button. The first screen is the 

 

 

 showing any alert or warning that exists 

on your controller. Each two letter code is an 

Alert Category. An 

 or 

 appear beneath any 

category that has an alert present.

QUICK REFERENCE CARD

RED BLK

BLK

BLK

STATION PROGRAM

RED

RED

04012019

 



Flow Alerts

 — Issue with flow hardware or flow 

feature programming. Fix the issue, then press     

button to clear alert then retest

Valve Alerts

 — Issue with valve electrical 

components or connections. Fix the issue, then 

press      button to clear alert then retest

Communication Alerts

 — Reset GPRS Status or 

call Customer Service for assistance

Water Window Warning

 — Calculated irrigation 

schedule exceeds the allowable irrigation time 

programmed Water Window

Water Day Warning

 — Calculated irrigation 

schedule exceeds number of allowable Water Days 

programmed in Water Day Mode

Station High Depletion

 — Reset Station 

Depletion from Manage Page of weathertrak.net or 

from Help menu — “Help : 12 — Current Depletion”

Hardware Alert

 — Issue with controller hardware. 

Call Customer Service for assistance

Subscription Alert

 — Call Customer Service to 

update data service plan

:

:

:

:

:

:

:



: