Turn ON
After the easyRX is connected according point 3.1 and the 12V supply is
switched on, all six visible LED on the top of the unit will illuminate once
for a period of one second. Then each second LED in the row will be
illuminated for one second and the other LED will be illuminated for
one second.
4.2
LED Indication and functions
CPA & AIS S.A.R.T. Alarm: This LED will illuminate, if a ship is inside
the defined and activated CPA Alarm radius (activated for default)
or an AIS SART message is received
Error: This LED will be illuminated, the supply voltage is low, the
VSWR value is bad (means bad antenna cable or connection)
Warning: This LED will be illuminated, if not all static data are pro-
grammed (e.g. MMSI)
AIS RX: This LED will be illuminated each time when an AIS message
is received.
5.
ADMINISTRATOR SETTINGS
Following settings can only be done by the manufacturer or
the administrator and cannot be changed by the end-user.
If you have inserted the dongle you will see one hidden