2

 

Safety 

2.1

 

Intended use 

The switch-over automatic must only be used for the purposes described in Chapter 

3.2 Product description

The  locally  applicable  regulations  concerning  accident  prevention,  occupational  safety  and  drinking  water 
protection must also be observed! 

2.2

 

Safety notices 

Carefully read and comply with the operating instructions prior to installation and use of the device! Work 
on the device and changes in the settings may only be carried out by properly instructed persons! 

 

Handling of chemicals, risks to humans and the environment 

 

In case of emergencies

 when handling chemicals, contact the emergency poison centre! 

 

Emergency number:  

Munich Emergency Poison Centre (or any other Poison Centre) 
Phone: +49 89 19240 

 
Excerpt from the Accident Prevention Regulations, GUV-V D 5 
 

Installation rooms for chlorination systems and storage rooms 
Section 3a. (1) Chlorination systems must be installed in lockable rooms and the chemicals intended for the 
chlorination must be stored in lockable rooms. 
Re Section 3a Para. 1:  

This requirement ensures that chlorination systems and chemicals shall be protected against weather effects 
and unauthorised access. 
(2) Rooms in accordance with Para. 1 must not be intended for the permanent presence of persons. 
Re Section 3a Para. 2:  

…… A “permanent” presence is given when persons are present in the room for more than 2 hours per day. 
Repair and maintenance work on the chlorination system are exempt from this. 

 

Protective measures and rules of conduct 

DANGER! CORROSIVE! SAFETY EQUIPMENT!  

The switch-over automatic is used to dose chemicals such as chlorine solution, pH 
reducer (acid) or flocculant from the delivery container. 

Ensure that the correct container / chemical is used! Different chemicals can react 
strongly with each other when mixed and release toxic fumes. For this reason, the 

greatest possible care must be taken when working with chemicals! Face protection, 
protective gloves, protective apron, boots. 

Store chemicals in such a way that they are not accessible to unauthorised persons. 
When storing chemicals, the chemical manufacturer's safety data sheets must be 

complied with. 
 

Fore more information, see the chemical manufacturer's safety data sheets! 
 

 

 

Содержание UMAP NT35-R

Страница 1: ...Item No OI No BA SW 017 03 Umschaltautomatik Typ UMAP NT35 R EN docx Language EN Operating and installation instructions Switch Over Automatic Type UMAP NT35 R...

Страница 2: ...mmissioning 8 4 4 Description of the control 9 4 5 Replenish consumables 9 5 Maintenance care faults 10 5 1 Device maintenance 10 Open and close the housing 10 5 2 Trouble shooting 10 6 Decommissionin...

Страница 3: ...ces as well as general notices DANGER DANGER denotes a safety notice which if disregarded may lead to serious or life threatening injuries or serious material damage CAUTION CAUTION denotes a safety n...

Страница 4: ...ar For these we assume a warranty of 1 2 year Our merchandise management programme requires an invoice for each delivery including warranty services When returning a defective component upon review yo...

Страница 5: ...and the chemicals intended for the chlorination must be stored in lockable rooms Re Section 3a Para 1 This requirement ensures that chlorination systems and chemicals shall be protected against weath...

Страница 6: ...oups Control electronic 2 suction sets with empty indicator foot valve and container cover 3 2 way switchover solenoid valve for switching between containers Figure 1 Switchover solenoid valve Options...

Страница 7: ...ic connection data Hose connection for suction lances 4x1 standard Sewer connection recommended At least DN25 Protection class IP44 Operating data Medium temperature Ambient temperature Humidity techn...

Страница 8: ...Mount the external dosing pump in a suitable location for example next to the mounting plate c Attach warning and notice signs in accordance with the locally applicable accident prevention regulation...

Страница 9: ...er the LED Container 1 goes out Suction continues from Container 2 d Only once Container 2 is empty the system switches back to Container 1 If Container 1 is still empty the dosing is automatically sw...

Страница 10: ...following applies for work on electronic components Never plug in or remove connectors unless the power has been deactivated As the person handling the device please discharge yourself electrostatical...

Страница 11: ...suction lances until the lines are clean control via the float switches 4 Disconnect the device from the power supply ATTENTION When recommissioning observe the instructions in the Commissioning chap...

Страница 12: ...Switch Over Automatic type UMAP NT35 R Index 03 Date modified 28 03 2022 OI No BA SW 017 03 Umschaltautomatik Typ UMAP NT35 R EN docx Page 12 of 14 7 Documents 7 1 Declaration of conformity...

Страница 13: ...Page 13 of 14 7 2 Wiring diagrams DANGER Risk of death due to high voltage All electrical work on the device must only be carried out by trained specialists in accordance with the applicable safety re...

Страница 14: ...0 Ribbon cable 10 pole L 300 mm 19541 Bulkhead connector PP 4x1 on both sides 11003 Union nut d 6 PP 1 4 15077 Hose PVC transparent 4 0x1 0 mm 12252 Suction lance NF d16 500 4x1 with empty switch thre...

Отзывы: