4.3

 

Splash sprinkler 

   

  

The scope of delivery includes a splash sprinkler made of stainless steel 

(16) to distribute the water drops over the stones of the oven. Connection 
for splash tubing is 3/8” female thread. 

Longer splash tubings are deliverable on demand. To prevent a back 
flowing if there´s a longer splash tubing it is possible to install a weak 

spring loaded non-return valve before the oven. If a non-return valve is 
installed a tube cutter is absolutely necessary! 

 

Option: 
For the assembly and safe fixing of the splash sprinkler, we offer a 

grommet with two threads 3/8” made of stainless steel. About 10-15cm 
over the oven, a app. 18mm hole is drilled into the sauna wall. 

Furthermore, the wall holder with the rosette is pushed inside. The rosette 

is fixed together with the delivered V4A screws on the sauna wall. Now the 
splash sprinkler can be screwed-on over the sauna stones. Use only teflon 

band for sealing to keep the cleaning of the sprinkler simply. 

 
 

 

 

  

 

 

 

wall holder 

option 

splash 
sprinkler 

 

scope of 

delivery

 

 

Содержание SAUNA-Plus VII

Страница 1: ...tment of the dosing 5 3 The dosing pump 6 3 1 Changing the hose set 6 3 2 Dosing valve 7 3 3 Fragrance canister 7 4 Installation Taking the unit into operation 7 4 1 Installation 7 4 2 Electrical conn...

Страница 2: ...ve 9 into the water that streams to the oven A a result it is ensured that the fragrance concentrate is only dosed when there s pressure in the water tubing Additionally the installed security combina...

Страница 3: ...connections for PTFE hose 6x1 push button for external control clock timer 2 2 The controller 2 2 1 Cycle pause in minutes The cycle time time from splash to splash is adjustable from 10 to 60 minute...

Страница 4: ...T pump test of the fragrance pump for 20 seconds afterwards the operation LED blinks the controller waits for a readjustment T valve test of the solenoid valve for 20 seconds afterwards the operation...

Страница 5: ...the controller The lead time can be adjusted to 0 30 60 or 120 seconds see wiring diagramme 2 2 7 Adjustment of the dosing The cycle time time from splash to splash is adjusted by the left rotary knob...

Страница 6: ...It is extraordinary safe in its function an in addition to this very easy to handle see mounting Fragrance concentrates are extremely aggressive The used dosing hose is resistant against the most con...

Страница 7: ...e canister The SAUNA Plus VII is delivered to be mounted on the wall the fragrance canister volume 1 5 l is pre mounted at the mounting plate 4 Installation Taking the unit into operation 4 1 Installa...

Страница 8: ...an also be pre installed ex works The connection for the water supply at the ball valve is for the splash tubing 3 8 The fragrance canister has to be filled and the suction tube has to be hung into it...

Страница 9: ...fore the oven If a non return valve is installed a tube cutter is absolutely necessary Option For the assembly and safe fixing of the splash sprinkler we offer a grommet with two threads 3 8 made of s...

Страница 10: ...hen there s a need to check it For this purpose release the dosing hose and screw out the dosing valve If you blow through the valve from the screw in side it has to be hermetically sealed If this is...

Страница 11: ...bove Check the function of the pump Pull the suction hose of the pump out of the fragrance canister does a air bubble appear in the hose Is it aspirated If yes the suction function of the pump works I...

Страница 12: ...operation manual SAUNA VII 07 12 page 12 of 14 Open all ball valves Clean filter central filter in technical room Test every single function component with the test switch 6 Wiring diagramme...

Страница 13: ...rommet felt EPDM 12709 pump motor 13557 mounting screws 17067 hose holder with dosing hose 13358 dosing hose with hose clamp 12782 Control housing ABS with imprint 16878 knob for control board 11031 v...

Страница 14: ...nce flexible pressure tubing PTFE 4x1 Identification Article no ball valve MS 10423 oblique sitting filter MS 11479 protection group 11465 solenoid valve Va 15072 solenoid valve connector 13082 dosing...

Отзывы: