Technical Data 

 

The unit consists of: 

 

-

 

water  connection ½“ female thread (app. 150l per hour) 

-

 

solenoid valve  ½“  

-

 

peristaltic pump 12-24VDC for fragrance 

-     controller with connector for ore-indiation of the splash 230VAC 

-

 

connector for push-button or external start device 

-

 

voltage supply 230VAC 1,25A 

-

 

splash sprinkler 3/8“ female thread 

-

 

measures 44x41x17 cm 

 

-

 

fragrance: 

 

up to 15 ml pro Aufguss  

-

 

water consumption:  up tp 800 ml per splash at adjustment 100% 

-

 

cycle time: 

 

10-60 Minuten

 

 

options 

 

-

 

tube cutter (if the splash tubing does not fall) 

-

 

enlargement for the splash sprinkler 

-

 

connections for PTFE hose 6x1 

-

 

push-button for external control 

-

 

clock-timer 

 

2.2

 

The controller 

 

 

2.2.1   Cycle - pause in minutes 

 

The cycle time (time from splash to 

splash) is adjustable from 10 to 60 
minutes. After the lapse of the cycle 

time the times for the dosing of water 
and fragrance run accordingly. The 

operation time of the fragrance dosing 

is limited to the opening time of the 
solenoid valve by the pressure switch. 

If the unit is operated externally (e.g. 
by push-button) the pause time is 

according to a locking time in which 
no further splash can be started. 

 

2.2.2

 

Splash quantity

 

 

 

The dosing times are adjustable by 
the rotary knobs from 0 to 20 

seconds. During this time the max. 

quantity that is dosed is 0.8l water 
with 15ml of fragrance. 

 
Attention: fragrance can only be dosed into flowing water!!! 

Содержание SAUNA-Plus VII

Страница 1: ...tment of the dosing 5 3 The dosing pump 6 3 1 Changing the hose set 6 3 2 Dosing valve 7 3 3 Fragrance canister 7 4 Installation Taking the unit into operation 7 4 1 Installation 7 4 2 Electrical conn...

Страница 2: ...ve 9 into the water that streams to the oven A a result it is ensured that the fragrance concentrate is only dosed when there s pressure in the water tubing Additionally the installed security combina...

Страница 3: ...connections for PTFE hose 6x1 push button for external control clock timer 2 2 The controller 2 2 1 Cycle pause in minutes The cycle time time from splash to splash is adjustable from 10 to 60 minute...

Страница 4: ...T pump test of the fragrance pump for 20 seconds afterwards the operation LED blinks the controller waits for a readjustment T valve test of the solenoid valve for 20 seconds afterwards the operation...

Страница 5: ...the controller The lead time can be adjusted to 0 30 60 or 120 seconds see wiring diagramme 2 2 7 Adjustment of the dosing The cycle time time from splash to splash is adjusted by the left rotary knob...

Страница 6: ...It is extraordinary safe in its function an in addition to this very easy to handle see mounting Fragrance concentrates are extremely aggressive The used dosing hose is resistant against the most con...

Страница 7: ...e canister The SAUNA Plus VII is delivered to be mounted on the wall the fragrance canister volume 1 5 l is pre mounted at the mounting plate 4 Installation Taking the unit into operation 4 1 Installa...

Страница 8: ...an also be pre installed ex works The connection for the water supply at the ball valve is for the splash tubing 3 8 The fragrance canister has to be filled and the suction tube has to be hung into it...

Страница 9: ...fore the oven If a non return valve is installed a tube cutter is absolutely necessary Option For the assembly and safe fixing of the splash sprinkler we offer a grommet with two threads 3 8 made of s...

Страница 10: ...hen there s a need to check it For this purpose release the dosing hose and screw out the dosing valve If you blow through the valve from the screw in side it has to be hermetically sealed If this is...

Страница 11: ...bove Check the function of the pump Pull the suction hose of the pump out of the fragrance canister does a air bubble appear in the hose Is it aspirated If yes the suction function of the pump works I...

Страница 12: ...operation manual SAUNA VII 07 12 page 12 of 14 Open all ball valves Clean filter central filter in technical room Test every single function component with the test switch 6 Wiring diagramme...

Страница 13: ...rommet felt EPDM 12709 pump motor 13557 mounting screws 17067 hose holder with dosing hose 13358 dosing hose with hose clamp 12782 Control housing ABS with imprint 16878 knob for control board 11031 v...

Страница 14: ...nce flexible pressure tubing PTFE 4x1 Identification Article no ball valve MS 10423 oblique sitting filter MS 11479 protection group 11465 solenoid valve Va 15072 solenoid valve connector 13082 dosing...

Отзывы: