Granudos 45/100-CPR Touch XL + Touch + S5
Dosing unit
Index: 02
Date modified: 06/06/2019
OI No.: BA SW 003-02 Granudos 45-100 CPR Touch+Touch+S5-Dosiereinheit EN.docx Page 34 of 58
2.
Push the yellow roller support provided with the delivery
onto the axle.
3.
Insert the hose bracket into the guides of the casing until it
firmly snaps into place.
4.
Turn the roller support counter-clockwise while carefully
pushing the hose inside the housing until the entire hose is
contained in the hosing.
Now replace the lock washer and the transparent pump cover. This completes the installation
of the roller support.
For dismantling the roller support and the hose bracket, please proceed in the reverse
sequence.
Plug the safety plug in a corresponding socket.
5.2.2
Prepare acid dosing for operation
PROTECTIVE CLOTHING!
Personal safety equipment must be put on before starting work with
chemicals: Protective gloves, apron, face protection, boots.
The specifications for each chemical listed in the safety data sheets
must be observed.
Connect/change acid canister
Toxic fumes may occur when handling acids. Do not inhale any fumes.
1.
Unscrew the screw cap with the suction lance from the empty acid canister, place the
suction lance in the collecting basin, and immediately close the empty canister, using the
original screw cap. (not applicable during initial commissioning)
2.
Lift the empty canister out of the collecting basin.
3.
Put the full acid canister into the collecting basin
Figure 22,
Insert roller support
Figure 23,
Insert the hose bracket
Figure 24,
Turn roller support