Fragrances dosing, type DUFTDOS 0-T
Index: 02
Change date: 01/07/2020
Operating instructions no.: BA DW 016-02 Duftdos-0-T EN 16621-17551.docx
Page 17 of 24
7.1.3
Check function of the pump
Press the test button. The lock washer must rotate.
Check suction function of the pump
1.
Draw the suction hose of the pump out of the container.
2.
The pump must suck air, forming an air bubble in the dosing pipe.
If no air is sucked, the suction function is defect.
3.
Afterwards deaerate the dosing pipe.
See Section 5 Commissioning.
Fault removal
CAUTION !
Fragrance concentrates can be harmful for the health!
In case of works on the suction or dosing pipe, wear protective gloves and protective
glasses.
Fault table
Fault
Possible cause
Actions
The device does not connect
Power supply interrupted
Steam generator disconnected (if
coupled with steam generator)
Check the power supply
Connect steam generator
Device without function
Circuit board defect
Send in the circuit board
Dosing pump without function
Pump motor defective
Check / exchange the pump motor
No fragrance dosing
Container with fragrance
container empty
Air in the dosing pipe
Fragrance pump defective
Hose of the dosing pump defect
Roller carriers worn out
Dosing valve blocked
Fragrance concentrate dirty
Refill container
Deaerate dosing pipe
Check / exchange the pump
Exchange the hose
Exchange the roller carrier
Check / clean / exchange dosing valve
Visual check of the fragrance
concentrate on transparency and
cleanliness. Exchange dirty concentrate