background image

Fragrances dosing, type DUFTDOS-0-Compact

 

 

Index: 01 

Change date: 01/12/2017 

Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx 

Page 9 of 21 

4

 

Installation 

The work described here may only be performed by appropriately trained specialist staff or by a specialist 
company. 

 

Selecting the place of installation 

The place of installation must have the following characteristics: 
1.

 

The place of installation must be protected against frost. 

2.

 

The device must be protected against direct sunlight.  

3.

 

An electrical mains connection must be available. 

4.

 

Good air supply and extraction are recommended for the installation room. 

 

Installation information (installation suggestion) 

The device is assembled in the technical room at a wall. The dosing pipe to the steam pipe must be as short 
as possible. 
Consider the space required for operation and maintenance of the device, see 

Section 3.4 Technical data

 

 

Warning and information signs according to the locally valid accident prevention regulations are to be 
provided at the intended positions. 

 

Mounting diagram 

 

 

 

Figure 5, Installation suggestion 

 

Steam cabin 

Steam pipe 

Dosing pipe 

Dosing valve 

Lock the plug 

socket DUFTDOS 

with steam gener-

ator 

Steam generator 

Содержание DUFTDOS-0-Compact

Страница 1: ...Item no 17630 Language EN Operating instructions Fragrances dosing for steam rooms Type DUFTDOS 0 Compact...

Страница 2: ...ion 9 Selecting the place of installation 9 Installation information installation suggestion 9 Mechanical installation 10 Hydraulic installation 10 Electrical installation 10 5 Commissioning 11 Commis...

Страница 3: ...device with appro priate accessories The operating instructions must be carefully read before using or maintaining the device and have to be stored in immediate proximity of the device Target group O...

Страница 4: ...ed We provide a warranty for half a year on those parts Our ERP program requires an invoice for each delivery also for warranty services Customers will receive a credit note after returning the faulty...

Страница 5: ...s and fragrances is provided in the safety data sheets of the fragrance manufacturers With the fragrance dosing a fragrance concentrate is mixed with the fragrance concentrate and is conveyed into the...

Страница 6: ...trate in the steam pipe of steam rooms Function The fragrance concentrate is dosed through the hose pump passing the dosing pipe into the steam pipe The pump must be connected in such a way that it ca...

Страница 7: ...pump according to the mainte nance plan or whenever fragrance is topped up 3 2 2 Dosing valve option The valve is a combined spring loaded non return valve and dosing valve In case of a defect of the...

Страница 8: ...possible transport damage immediately after receipt ATTENTION The device can get damaged by frost or high temperatures Prevent exposure to frost during transport and storage Do not store the device ne...

Страница 9: ...t 3 An electrical mains connection must be available 4 Good air supply and extraction are recommended for the installation room Installation information installation suggestion The device is assembled...

Страница 10: ...team pipe 2 In case of a bigger distance between the installation place and the dosing valve install a transparent protec tion pipe for the dosing pipe if necessary 3 Connect the dosing pipe at the ri...

Страница 11: ...ee Section 9 3 The device is provided with factory settings when it is delivered Adapt the regulation parameters during the start up on the desired operating mode Commissioning works Ensure that the d...

Страница 12: ...y flammable CAUTION Fragrance concentrates can be harmful for the health Wear protective gloves and protective glasses See the safety data sheet of the manufacturer of the fragrance 1 Screw off the co...

Страница 13: ...ve glasses ATTENTION Aggressive fragrance concentrates shorten the lifetime of the hoses If possible avoid aggressive fragrance concentrates Hint Refill consumables in due time If the container is emp...

Страница 14: ...protect it against new connection Do not open the casing 7 1 1 Check replace hose set The device is mainly maintenance free The pump hose in the pump is subject to mechanical and chemical stress Each...

Страница 15: ...arts of the hose ties 5 Install the hose set see Section 7 1 1 Check replace hose set Figure 11 Hose set spare parts Legend 16 Hose black 15 Hose holder 31 Marking 32 Plier 2x 7 1 2 Check the dosing v...

Страница 16: ...protection gloves or protection glasses Fault table Fault Possible cause Actions The device does not connect Power supply interrupted Steam generator disconnected if coupled with steam generator Check...

Страница 17: ...perating materials are subject to specific regulations In cases of doubt information should be available from the institution responsible for disposal at your place of operation When this is not possi...

Страница 18: ...Fragrances dosing type DUFTDOS 0 Compact Index 01 Change date 01 12 2017 Operating instructions no BA DW 017 01 Duftdos 0 Compact EN 17630 docx Page 18 of 21 9 Documents Declaration of conformity...

Страница 19: ...EN 17630 docx Page 19 of 21 Terminal plan No terminal diagrams necessary Commissioning protocol instruction This protocol is to be completed by the commissioning technician All warranty claims expire...

Страница 20: ...ions no BA DW 017 01 Duftdos 0 Compact EN 17630 docx Page 20 of 21 Operating data sheet No operation data sheet necessary Maintenance protocol Perform the maintenance work listed in order to retain th...

Страница 21: ...m Options Device Pos Description Item no WDT Dosing set Dosing set compete 12596 Dosing valve VA complete 3 8 4x1mm 3m dosing hose PTFE 4x1 mm Dosing valve Dosing valve VA complete 3 8 4x1mm 15108 Sea...

Страница 22: ...ct installation 1 2 Settings made on control board and fragrance quantities adjusted to cabin size Type DS only Observe manufacturer specifications for fragrance concentrate 1 3 Hose pump roller suppo...

Страница 23: ......

Страница 24: ...ance year 20___ City street house number Device type Year of manufacture Serial number Activity Maintenance interval in months Month 1 Month 2 Month 3 Month 4 Month 5 Month 6 Month 7 Month 8 Month 9 M...

Отзывы: