Operating Instructions and Parts Manual

10

ELECTRICAL PRECAUTIONS - Before servicing a pump, ALWAYS shut off the main power breaker and then unplug the pump. Make sure you are NOT 

standing in water and are wearing insulated protective sole shoes. Under flooded conditions, contact your local electric company or qualifi ed licensed 

electrician for disconnecting electrical service prior to pump removal.

TROUBLESHOOTING CHART

Symptoms

Possible Cause(s)

Suggested Remedies

Pump will not  

start or run 

1.  Power off
2.  Blown fuse or tripped breaker
3.  Faulty pressure switch
4.  Motor overload tripped
5.  Low supply voltage

1.  Turn power on or call power company
2.  Replace fuse or reset circuit breaker
3.  Replace 30/50 pressure switch
4.  Let cool. Overload will automatically reset
5.  Contact an electrician

Motor hums but 

won't run

1.  Line voltage does not match selector switch
2.  Inadequate wiring
3.  Damaged or misalignment causing rotating parts 

to bind

4.  Low supply voltage

1.  Check line voltage and voltage selector switch (see Figure 7 on page 8)
2. Rewire
3.  Replace or take to service shop for repair

4.  Contact an electrician

Overload trips

1.  Low supply voltage
2.  Damaged or misalignment causing rotatin parts 

to bind

3.  High surrounding temperature
4.  Rapid cycling
5.  Inadequate wiring

1.  Contact an electrician
2.  Replace or take to motor replare shop

3.  Provide a shaded, well-ventilated area for pump
4.  See pump starts and stops too often section below
5. Rewire

Pump runs but 

delivers little to no 

water.

NOTE:

 check to 

make sure pump is 

primed before looking 

for other causes. 

Unscrew priming plug 

and see if water is in 

priming hole.

1.  Water level below pump intake
2.  Discharge not vented while priming
3.  Leak in suction piping
4.  Well screen or inlet clogged
5.   Clogged nozzle
6.  Air volume control disphragm ruptured
7.  Foot valve may be clogged or stuck closed
8.  Pump not fully primed

9.  Water level below maximum lift specification
10. Undersized piping
11. Gaseous well
12. Distorted venturi
13. Incorrect jet for application
14. Undersized pump
15. Pump cavitates, sounds like pumping gravel
16. Low supply voltage

1.  Lower suction pipe further into wall
2.  Open faucet to allow air to vent while priming pump
3.  Repair or replace to fix leak
4.  Clean or relace to remove obstruction
5.   Clear obstruction from nozzle
6.  Replace air volume control
7.  Clean or replace as needed
8.  Continue priming, pausing every 5 minutes to cool pump body. Refill pump 

as needed

9.  Select applicable pump and/or jet assembly
10. Replace as needed
11. Install baffle on pump intake to prevent gas from entering system
12. Inspect and replace
13. Purchase a jet matched to your system
14. Increase horsepower of pump
15. Increase suction plumbing diameter or decrease pipe friction
16. Contact an electrician

Pump starts and 

stops too ofen

1.  Water-logged tank (Conventional Tank)
2.  Air volume control tubing kinked or clogged
3.  Air volume control tubing connected to wrong 

opening on pump

4.  Incorrect tank pressure (pre-charged tank)
5.  Ruptured disphragm/bladder (pre-charged tank)
6.  Leak in house piping
7.  Foot valve or check valve stuck open
8.  Motor overload tripping
9.  Improperly adjusted or damage pressure switch

1.  Replace tank or air volume control
2.  Clean or replace as needed
3.  Move to correct pump opening 

4.  Add or release air as needed
5.  Replace tank
6.  Locate and repair leak
7.  Remove and replace
8.   See overload trips section
9.   Replace 30/50 pressure switch

PRÉCAUTIONS ÉLECTRIQUES - Avant tout entretien ou réparation de pompe, TOUJOURS couper le courant au disjoncteur, puis débrancher la pompe. 

S'assurer de ne PAS rester debout dans l'eau, et porter des chaussures à semelles de protection isolées. En cas d'inondation, vérifier auprès de la 

société locale d'électricité ou d'un électricien agréé qualifié pour couper le service électrique avant le retrait de la pompe.

Содержание SWS Series

Страница 1: ...t 25 ft SWS50 1 2 30 711 674 638 601 565 529 40 543 506 470 433 397 361 50 375 338 302 265 229 193 SWS75 3 4 30 779 750 721 691 662 633 40 644 615 586 557 528 499 50 510 481 451 422 393 364 SWS100 1 3...

Страница 2: ...RIPTION Shallow well jet pumps are single stage residential water pumps designed for pumping potable water in applications where the water is located less than 25 feet vertically from the pump A press...

Страница 3: ...lectrical circuit checked by a licensed or certified electrician to make sure the circuit is properly grounded 12 The circuit voltage and frequency of electrical current must correspond with the speci...

Страница 4: ...ling the pump Sand will damage the pumping parts and seal The draw down level of the well should not exceed the maximum rated depth for the pump The capacity of the pump will be reduced and a loss of...

Страница 5: ...well or sand or sediment WILL be drawn into the system MISE EN GARDE Le clapet de pied DOIT au moins tre 45 7 cm 18 po du fond du puits sinon du sable ou des s diments POURRAIENT tre aspir s dans le...

Страница 6: ...the metal well casing or use a ground electrode furnished by the power company There is only one proper ground terminal on the unit The terminal s is located under the pressure switch cover is painte...

Страница 7: ...es the tank with the correct air to water ratio for the system to operate If the air volume control is good the pump will shut off at the desired cut off and will be adjusted correctly WATERLOGGED TAN...

Страница 8: ...eal seat 2 Carefully slip seal plate over shaft Do not disturb seal position in seal plate The seal plate must be orientated during assembly so the two screw holes are on a horizontal line across the...

Страница 9: ...pump with new parts in reverse order 14 Wipe down the seal plate to remove any debris or loose rust 15 Push the ceramic seat of the shaft seal into the seal plate using the cardboard ring provided to...

Страница 10: ...oot valve may be clogged or stuck closed 8 Pump not fully primed 9 Water level below maximum lift specification 10 Undersized piping 11 Gaseous well 12 Distorted venturi 13 Incorrect jet for applicati...

Страница 11: ...oncrete to prevent cave in D DRIVEN WELL Pipe with a pointed screen is driven into the ground below the water table The depth is usually less than 50 feet Available diameters are 1 through 2 E DRILLED...

Страница 12: ...ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM COMMERCIAL CODE OR OTHERWISE WITH RESPECT TO THE...

Отзывы: