Chapter 5: Configuring Sensor Settings
•
47
Setting
Description
Details
Loop Emulation
Size & Spacing
Makes your system
emulate a system
with inductive loops.
These settings are
read by a Click
contact closure
device, which uses
that information to
send contact closures
that are properly
timed to emulate a
given loop size and
spacing.
Use this if you used
the SmartSensor HD
to replace loops,
and the rest of
your system is still
configured to deal
with loops. This way
the system keeps
getting the sort of
data it expects to see.
Legacy Protocols
SS105
Sets the sensor
to use the SS105
communication
protocol.
This
doesn’t turn off
native SSHD
protocol.
Click this checkbox
if your backend
system was
originally configured
for a SmartSensor
105 and is still
expecting data in
SS105 protocol.
RTMS (X3)
Sets the sensor
to use the RTMS
communication
protocol (although
only a portion of the
RTMS commands
are emulated).
This doesn’t turn
off native SSHD
protocol.
Click this checkbox
if your controller or
backend system
was originally con-
figured for an RTMS
model X3 sensor
and is still expect-
ing data in RTMS
protocol.
Note.
Changing
loop size will affect
occupancy numbers
in the interval
data, but adjusting
these settings will
not modify the
reported vehicle
length or speed.
Note.
For a
SmartSensor HD
in an RTMS-based
system: if your
system is set up
to poll the sensor,
turn on the RTMS
protocol so the
sensor can respond
to RTMS commands.
If your system is
simply listening for
data pushes from the
sensor, don’t turn on
the RTMS protocol.