Страница 1: ...er Developed by KRM Technology Inc dba iAutomate com 4305 State Bridge Road Suite 103 251 Alpharetta GA 30022 Phone 678 388 9508 Toll Free 888 949 1388 Fax 678 388 9508 Email support iautomate com or...

Страница 2: ...out and Additional Timeout 18 4 3 7 Adding Tags 19 4 3 8 Address 19 4 3 10 Name 19 4 3 11 Additional Timeout 20 4 3 12 Saving Changes and Additional Control Buttons 20 4 3 13 Enable Debug Logging 20 4...

Страница 3: ...can be discretely concealed in walls ceilings and doorways to identify and track Tag activity The R500HA can simultaneously read multiple RFID Tags at ranges of up to 450 feet free air and can also re...

Страница 4: ...circuitry and therefore do not need to be added The network operates at 57 600 baud with data being sent bidirectionally The ReaderNet may be supplied with power from multiple points within the netwo...

Страница 5: ...other brands of RJ45 Connectors No home automation installer should be without this time saving tool and a bag of EZ RJ45 Connectors Figure 4 2 1 RF Basics Relating to the R500HA RFID Reader A typical...

Страница 6: ...distance an RF Transmission will travel is primarily determined by the transmitter s output power and the receiver and antenna s power GAIN and is influenced by environmental conditions and structure...

Страница 7: ...iAutomate com Part Number 2005 iAutomate com 4 11 05 R500HA R500HA Reader Installer Manual Page 7 of 31...

Страница 8: ...e of the coverage pattern of the R500HA Reader when using the supplied dipole whip antenna This is how the pattern would look with the Reader mounted vertically The tip of the antenna is where X Y int...

Страница 9: ...rmance of the Tags For Maximum range the angle of polarization of the Tag and R500HA RFID Reader should be the same In some instances the wiring between Readers can function as part of the antenna For...

Страница 10: ...Reader locations centralized under internal rooms but favoring outside driveway wall of Garage to maximize Automobile Tag Range A variety of antennas are available for longer range and exterior appli...

Страница 11: ...elds metal carts metal trash cans as well as plastics or fiberglass containing a high metallic content such as laptop and desktop computer systems office machines hospital equipment telephones etc as...

Страница 12: ...with Tamper Detect and Magnet T100 MS RFID Tag with Motion Sensor and Tamper Detect 3 1 4 The T1200 Wrist Band Tag Primary Use Use for patient monitoring pet monitoring personnel monitoring child moni...

Страница 13: ...le RFID Scripts and also registers the components with the operating system The Plug In can also be installed via the HomeSeer Updater Once the R500HA plug in is installed on your HomeSeer system it m...

Страница 14: ...n to activate it within HomeSeer Click on the drop down list under Select device to add and find the iAutomate RFID plug in If the plug in was installed correctly you should find it in the list simila...

Страница 15: ...ID InitIO Error 8012 The device is not open on line 0 These error messages are normal as the plug in does not know which COM port to use for the plug in To correct this and to set up your Readers and...

Страница 16: ...te com If you are able to successfully access the configuration screen it will appear similar to Figure 13 Figure 13 Part Number 2005 iAutomate com 4 11 05 R500HA R500HA Reader Installer Manual Page 1...

Страница 17: ...ader should be configured at a time because the plug in enumerates examines the R500HA network to find the single new Reader that exists on the network for which it does not already have a configurati...

Страница 18: ...SI values between 30 and 130 Readers that you wish to configure for the maximum range should be set to zero and anything 30 or higher will begin to affect the range at which Tags are detected 4 3 5 GA...

Страница 19: ...f zero 4 3 7 Adding Tags The plug in will only acknowledge signals from Tags that you have configured in the system The Tag s address number can be found on the Tag itself The portion of the configura...

Страница 20: ...on may be necessary to assist support personnel resolve issues with the plug in Turning this on unnecessarily will cause the plug in to slow and the log file to grow in size very rapidly 4 3 14 Reset...

Страница 21: ...value required for certain trigger types The trigger types and their features are described in the next sections 4 4 2 Enters Reader s Range As the name implies the Enters Reader s Range trigger is se...

Страница 22: ...is Moving trigger only the Tag and this trigger type need to be chosen the Reader selection is ignored If the selected Tag is moving and is in range of any of the Readers in the network this trigger w...

Страница 23: ...rigger the Greater Than RSSI trigger this trigger condition remains true and so the plug in will try to trigger the event as many times as it can causing the plug in and thus HomeSeer to suffer greatl...

Страница 24: ...which will never be true No Tags is ABSENT from all Readers Other than being a poor choice grammatically this means that all Tags are present at all Readers in the system which although possible if th...

Страница 25: ...plug in or This BETA RFID Plug In Expires at the end of the day today Please get the production version Download the Current Version of the plug in via the HomeSeer Updater Error opening COM port erro...

Страница 26: ...HomeSeer s performance Delete the HomeSeer log file or archive the file HomeSeer will create a new file automatically Your iAutomateRFID log file is too large logging is being turned off The RFID Logg...

Страница 27: ...owed the shield works against you inducing noise 5 Hooking up eight wires Reader 1 wires differently than readers 2 10 However ONLY four wires are connected to each RJ45 Connector and Reader Jack rega...

Страница 28: ...t Authority Singapore FCC Federal Communications Committee Industry Canada Canadian Certification Body C Tick Australia and New Zealand SAR Specific Absorption Rate HERO Military Hazards of Electromag...

Страница 29: ...iAutomate com 5 2 Tag and Reader Worksheet Tag Number Reader Number Type Model Name Timeout Notes Part Number 2005 iAutomate com 4 11 05 R500HA R500HA Reader Installer Manual Page 29 of 31...

Страница 30: ...UTION AND USE Having granted the standard license the licensee may use one copy of the corresponding The Software to integrate to the applications installed in one workstation providing that each APPL...

Страница 31: ...ent of the Agreement between the parties on the subject matter and merges and supersedes all other or prior understandings purchase orders agreements and arrangements The laws of the State of Georgia...