5. Press “TIMER”:
Press “TIMER” to set the working hours of the unit.
1. Time set for switching on:
When the appliance is powered off or in standby mode, press Timer 1 to 24H or flexible
working time to set up a required operating time. When the unit reaches the requested
time, the unit switches on and starts to work automatically.
2. Time set for shutdown:
When the appliance is powered on, press Timer 1 to 24H or flexible working time to set the
unit’s running hours. Once the time is set, the remaining hours are shown on the screen
until time is up.
3. Please note: The memory function will not work when the timer is set for shutdown.
Automatic Defrosting
A working cycle: When the appliance works in low temperatures, frost may appear on the surface of the
evaporator. To ensure the unit performs well in these conditions, an automatic defrost function is fitted to
the appliance.
1
)
When a room temperature drops down to 16
℃
or less, the compressor works for 25 minutes
dehumidifying then cuts off. The fan blower then keeps running for 7 minutes to defrost in
2
)
When defrost
,
Symbol of defrost displayed on LCD, and the symbol of
dehumidification goes out.
3
)
When defrost
,
Symbol of defrost displayed on LCD, the compressor is shut off, fan runs at
high speed.
Water Tank Full Warning
When the water tank is full, a buzzer will alarm 10 times (for about 5 seconds), and the symbol
that
indicates a full tank is displayed on LCD screen. Note all other symbols turn to orange and the appliance
cuts out. At this point the water tank must be removed, emptied and reinstalled before the unit can operate
again. The interval of dehumidifying lasts about 3 minutes because of the compressor protection.
Remove Water Reservoir as Arrow Direction
!