Страница 1: ...Wavecom User Manual Certificate of Warranty and Product Support Information TnP 3PLM 20A 32A 50A 3 Phase Portable Appliance Test and Print Kit...
Страница 2: ...duct that proves to be defective This warranty does not apply if the product has been damaged by accident abuse misuse or mis application or as a result of service or modification by anyone other than...
Страница 3: ...etent Person as well as any additional legislation or rulings in different states If in doubt the manufacturer suggests the user contact their responsible authority For maximum safety always ensure th...
Страница 4: ...Appliance Construction 31 Class 2 Double Insulated Construction 32 Testing of Electrical Equipment 32 Leakage Test 33 Earth Continuity Test 33 3 Phase Testing 33 Integrated Tests 33 No Connection No T...
Страница 5: ...PATS voucher valued at 30 GST for App Purchase through Google Playstore Shockproof Industrial Case 1 Roll 500 of White Labels 1 Roll of Printing Ribbon IEC Test Lead 500mm Orange USB A to USB B Interf...
Страница 6: ...al equipment must have Knowledge and practical experience of electricity and its hazards A clear understanding of precautions to avoid danger The ability to recognise at all times whether or not it is...
Страница 7: ...may slow down the app significantly We strongly recommend that you do not install other apps on this tablet to ensure the stable operation of the WinPATS App Before using your tablet with WinPATS you...
Страница 8: ...ned off by pressing and holding the ENTER button until you hear a beep and the LCD screen backlight turns off You will then see charging information displayed on the screen Once the battery is fully c...
Страница 9: ...n sending the TnP 3PLM for calibration please turn off the battery isolation switch which is located in the storage compartment of the tester If you have any questions about the battery of your TnP 3P...
Страница 10: ...ready you can log in straight away using the details provided to you Otherwise tap Register Company to set up your Company Account you will be prompted to enable WinPATS permissions this allows you to...
Страница 11: ...ed and your TnP 3PLM in front of you Go to the Bluetooth settings in your Tablet s settings menu Ensure that Bluetooth is enabled then select your TnP 3PLM from the list of available devices ensure yo...
Страница 12: ...nnect your printer in addition to your TnP 3PLM as shown Connecting your TnP 3PLM to your Tablet via USB To connect your TnP 3PLM to your tablet via USB you will need A USB A to USB B cable 1 Included...
Страница 13: ...company using the dropdown menu then edit suspend lock the user but keep the profile or delete the user To add a new User tap the symbol next to the dropdown menu Fill out the form including selectin...
Страница 14: ...iple ways an item can be tested using WinPATS This part will cover the two most common methods Both of these methods require that your TnP 3PLM to be connected to your tablet see above Connecting via...
Страница 15: ...ind the item in your Inventory Side Menu Database Inventory Once you are on the Item Information screen review the Assigned Test Sequence and ensure the correct test will be conducted Set up the item...
Страница 16: ...s in installed in your barcode scanner The LED on your scanner should begin flashing blue indicating it is ready to be paired to your tablet Now open the Bluetooth Settings menu of your tablet and tur...
Страница 17: ...3PLM is running on battery power no Bluetooth connection TnP 3PLM is running on battery power active Bluetooth connection TnP 3PLM is running on mains power and is charging no Bluetooth connection TnP...
Страница 18: ...e Mains Supply Test Page 26 TnP 3PLM Menu System The menu system of the TnP 3PLM is divided into 3 pages Menu A and B contain single phase tests while Menu C contains three phases tests The TnP 3PLM h...
Страница 19: ...to the IEC socket of the TnP 3PLM 4 Connect earth clip to any exposed metal on the device If this is not possible you can use a metal mesh braid to establish an earth connection sold separately 5 Navi...
Страница 20: ...lead or power board into the appliance test socket 4 Connect the IEC 550 Orange lead to your extension lead 5 Navigate to Main Menu A then Press the F3 key to begin the test 6 Read and record results...
Страница 21: ...Menu B F2 Note Leakage Tests can only be conducted when connected to mains power The Leakage Test is an alternate method to perform insulation resistance tests Leakage testing is a major function of t...
Страница 22: ...3PLM then clamp it onto earthed metal on the appliance 5 If testing an RCD plug the IEC 550 Orange Cable into the IEC socket of the TnP 3PLM then plug it into a socket on your RCD and turn that switch...
Страница 23: ...n Isolation Transformer designed specifically for the purposes of field RCD tripping Do not use these transformers for any other purpose Rated 240VAC In 240VAC Out 30VA Fuse protected Primary Winding...
Страница 24: ...d maintains the last set trip current value If the user wishes to change the value of the trip current the following steps enable the changes Press F2 from the options menu to display test current F1...
Страница 25: ...4mA trip current To enter the RCD menu from Main Menu B press the F3 button Then to set up a Ramp Test press F2 Before performing an RCD Ramp Test the TnP 3PLM should be configured to ensure an accura...
Страница 26: ...op Procedure 1 Complete a Visual Inspection 2 Plug device into the Three Phase Test Socket 3 Plug the IEC Clamp Cable into the IEC socket of the TnP 3PLM 4 Connect earth clip to any exposed metal on t...
Страница 27: ...est applies power to the Device Under Test and measures any imbalance or leakage current The leakage is tested to the limits of the class types specified in the Standard AS NZS 3760 i e Class 1 5mA as...
Страница 28: ...Features Electrical parameters are displayed as Volts Amps Watts and Volt Amps These electrical parameters will be displayed on the Testers main screen display Select from the 4 Test available in Met...
Страница 29: ...equired to support the computing equipment in question Watts and VA Detailed Explanation The power drawn by equipment is expressed in Watts or Volt Amps VA The power in Watts is the real power drawn b...
Страница 30: ...evel Greater than 1M Measurement 0 1 to 10 0M Continuity Polarity Test 250VAC check continuity and polarity of leads Displays Pass Fail Leakage Test Leakage Current 0 to 30 0mA at 200 to 265V Earth Le...
Страница 31: ...All safety devices and systems are in good working order i e overload latches buttons No dust or dirt obstructs any exhausts or ventilation outlets All controls are working properly and are secure an...
Страница 32: ...ion against electric shock which is equivalent to double insulation Testing of Electrical Equipment Many testing personnel have some reservations in testing sensitive electronic equipment using a 500V...
Страница 33: ...NZS 3760 2010 Unique Earth Bond Test Feature The Earth Bond test duration can be controlled by the user by pushing the ENTER button during the test This will extent the test time by 30 seconds The TnP...
Страница 34: ...ugged into the TnP 3PLM and that it is switched on If the device is not plugged in and the TnP 3PLM detects that no device is present and prompts the user to plug in an appliance to continue the test...
Страница 35: ...iew window 3 Feed Button 4 Label Exit Chute 5 Top Cover Release Lever 6 Power Switch 7 Power Socket 8 USB Interface 9 RS 232C Interface 10 SD Card Slot 11 Ribbon Rewind Hub 12 Print Head 13 Ribbon Rew...
Страница 36: ...n in step 1 before loading a new ribbon To remove this ribbon simply hold the ribbon roll and move it to the right away from the blue gear 1 Open the top cover of your Printer 4 Push the ribbon into t...
Страница 37: ...ty roll uising a piece of tape try to attach the ribbon as straight as possible 5 Next gently pull the ribbon out up and over the print head around to the empty core 7 Use the ribbon rewind gear to ti...
Страница 38: ...maximum open angle 1 Separate the Label Holders by gently pulling them in opposite directions 2 Insert the media between the label holders as shown 3 Using the Media Guide Adjuster Knob adjust the Me...
Страница 39: ...utton Function Feed labels When the printer is ready press the button to feed one label to the beginning of next label Pause the printing job When the printer is printing press the button to pause a p...
Страница 40: ...prior to calibrate the sensor Gap Black Mark Calibration Self test and Dump Mode While calibrating the gap black mark sensor printer will measure the label length print the internal configuration self...
Страница 41: ...wing procedures 1 Turn off the power switch 2 Hold on the button then turn on the power switch 3 Release the button when LED turns green after 5 amber flashes Any green will do during the 5 flashes Th...
Страница 42: ...lowing guide lists the most common problems that may be encountered when operating this bar code printer If the printer still does not function after all suggested solutions have been invoked please c...
Страница 43: ...ization and gap black mark calibration Paper Jam Gap black mark sensor sensitivity is not set properly sensor sensitivity is not enough Calibrate the gap black mark sensor Make sure label size is set...
Страница 44: ...nd a cotton swab or lint free cloth Clean the platen roller when changing a new label roll Tear Bar Peel Bar Use the lint free cloth with 100 ethanol to wipe it As needed Sensor Compressed air or vacu...
Страница 45: ...cifications Model changes may be found on the Wavecom website www wavecom com au At the time of developing this manual all care and consideration for accuracy has been implemented Wavecom accepts no r...
Страница 46: ...most aggressive and comes highly recommended for use in the electrical test and tag industry there should be no butterflying once applied Order Information Standard Tags 500 Tags per Roll Part no WCM...
Страница 47: ...rong durable synthetic materials and come with an adhesive backing that ensures that when the overlay is stuck down it stays stuck This allows you to use your standard Wavecom tags in harsh environmen...
Страница 48: ...P 08 9353 1943 F 08 9353 4319 E saleswa wavecom com au Wavecom VIC Mark Kennedy M 0430 299 164 P 03 9897 4711 F 08 8243 3501 E service wavecom com au The TnP 3PLM is proudly designed and manufactured...