wattstopper FM-105 Скачать руководство пользователя страница 1

FM-105

Line Voltage • High Frequency

Occupancy Sensor

Installation Instructions

DESCRIPTION AND OPERATION

The FM-105 high frequency occupancy sensor uses ultra-

high-frequency radio waves, also known as “microwaves” 

and the principle of the Doppler Effect to detect motion. 

The sensor sends out radio waves that bounce off of nearby 

surfaces and return to the sensor. Motion in the area 

changes the speed of the waves returning to the sensor. The 

sensor detects the change and interprets it as occupancy. 

This causes the sensor to turn ON the load.
High freqency radio waves can penetrate certain materials, 

therefore, the FM-105 can be installed behind a luminaries’ 

plastic or glass lens.  
The FM-105 can be used in a water-tight non-metallic 

box or water-tight luminaire for wet or damp location 

applications.

Daylighting Control

The FM-105 also has daylighting control capability. The 

daylight control on the FM-105 is a “HOLD-OFF” type. The 

sensor stops the load from turning ON if the ambient light 

is greater than the daylighting setpoint. If the load is already 

ON, the sensor will not turn OFF the load due to high 

ambient daylight.

SENSOR COVERAGE AREA

The coverage pattern may vary based on sensor location 

and characteristics of surrounding material. Shield 

placement, or the use of the second shield may alter the 

coverage pattern.

Wall Mount

 

6’ (2m)

12’ (4m)

18’ (5.5m)

MAX.

20’ (6m)

MIN.

3’ (1m)

Ceiling Mount 

6’ (2m)

12’ (4m)

18’ (5.5m)

MAX.

MIN.

FM-105

inside

ceiling mount

fixture 

at 8’ (2.5m)

height

Call 800.879.8585 for Technical Support • www.wattstopper.com

FM-105 with shield and mounting foot 

(2 shields included)

SPECIFICATIONS

Voltages .......................................... 120/277VAC, 50/60Hz
Load Requirements
  @ 120VAC, 60Hz .................0-800W ballast or tungsten
  @ 277VAC, 60Hz ...................................0-1200W ballast
Trimpot Adjustments
  Light Level .........................................................2-200fc
 Range/Sensitivity ...........................3’ to 20’ (1m to 6m)
  Time Delay ...........................10 seconds to 30 minutes
Power Output ... 1 mW (similar or less than a cell phone)
Frequency .............................................................. 5.8GHz

INSTALLATION

CAUTION

TURN THE POWER OFF AT THE 

 

CIRCUIT BREAKER BEFORE 

INSTALLING THE SENSOR.

1. 

Determine the mounting location inside the luminaire or other 

suitable enclosure. If the daylight feature will be used, be sure 

to locate the sensor where daylight is not completely obscured 

from the sensor. 

2.  Attach a metal shield to the FM-105 so that the shield is 

located between the FM-105 and the lamp. If additional 

shielding is needed, attach the second optional shield to the 

other side of the FM-105. Make sure that the wiring terminals 

on the FM-105 are accessible.

3.  Put the plastic mounting foot onto the base of the FM-105 to 

secure the metal shield(s) in place.

4.  Secure the FM-105 assembly in place using screws through 

the plastic mounting foot.

5.  Connect the line voltage and load wires to the FM-105 

terminals as shown in the wiring diagram.

 

• 

Do not allow bare wire to show. 

 

• 

Make sure all connections are secure.

6.  Restore power from the circuit breaker.