Lync WQ-AS
SECTION 3: OPERATION
L- OMM-007_A
•
5/6/2022
Technical Support • (800) 433-5654 • Mon-Fri, 8 am - 5 pm EST
12
of
42
13. Use Teflon tape and install the AquaSolve inlet sample port assembly on the inlet side of
the AquaSolve tank (see Figure 3-1).
14. Use Teflon tape and install AquaSolve vacuum relief valve on the outlet side of the
AquaSolve tank (see Figure 3-1).
Figure 3-1 WQAS AquaSolve Header Connections
NOTES:
•
The Lync Cartridge Filter is inspected prior to shipment to assure it is free from
manufacturing defects. Before installation, however, please check the lid's O ring to
ensure it is in place.
•
If water hammer is evident, install water hammer arrestors before the system.
3.4.
Electrical Connections
It is the responsibility of the end user to ensure that the installation is done according to local
codes and regulations. Plug in the power cord(s) into an appropriate outlet (refer to
specifications table) that is installed and grounded in accordance with all local codes and
ordinances.
NOTE:
The system MUST be plugged into an uninterrupted power supply that matches the
rated power requirement of the system. In European installations, the appliance is to be
supplied through a residual current device (RCD) having a rated residual operating current
not exceeding 30 milliamps.
WARNINGS!
This appliance must be grounded. In the event of a malfunction or breakdown, grounding will
reduce the risk of electric shock by providing a path of least resistance for electric current.
This appliance is equipped with a cord having an appliance-grounding conductor and a
grounding plug. The plug must be plugged into an appropriate outlet that is installed and
grounded in accordance with all local codes and ordinances.
Improper connection of the appliance-grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or service representative if you are in doubt whether
the appliance is properly grounded. Do not modify the plug provided with the appliance; if it
will not fit the outlet, have a proper outlet installed by a qualified technician.