background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yellow

 

Red

 

Green

   

0

 

0

 

0

 

Automatic mode, HEATER stopped

 

0

 

1

 

0

 

Automatic mode, 

HEATER operating

 

1

 

0

 

0

 

Manual 

mode OFF forced

 

1

 

1

 

0

 

Manuel 

mode 

HEATER forced

 

or 

1

 

or 

1

 

quick flash

 

Reception of an order, 

4 flash

 

or 

1

 

or 

1

 

1

 

Waiting for a 

configuration 

signal (cf. configuration)

 

0

 

0

 

slow blink

 

ERROR see repair sequence bellow:

 

 

 
 

Repair instructions

 

- Verify the emitter batteries. 
- Verify the emitter/receiver range. 
- No perturbation by an apparatus at less than 50cm of 
the receiver. 
- No perturbation by an apparatus on the 433.92 MHz 
frequency (continuous transmission).

 

By pressing on the push 

button

 

nothing happens

 

 

- Verify that the receiver is correctly connected 
- Verify main power supply (230VAC)

 

 

Operating temperature

 

0°C - 50°C  (or 32°F 

– 122°F)

 

Electrical

 

Protection

 

 

Class II   -   IP44

 

Power Supply

 

230Vac 50Hz

 

Radio frequency and

 

Receiving zone

 

433.92 MHz, <10mW. 
Range of approximately 100m in open space. 
Range of approximately 30m in residential environment.

 

 

certifications

 

CE. EN 300220-3, 
EN 301489 (Radio frequency certifications)

 

Output

 

Relay 12A 250Vac

 

 

USER GUIDE 

GB

 

 

1 channel RF Receiver 230Vac  (EFHRFR 001)

 

 
 
 
 
 
 
 
 
 
 
 
 

 

MODES DESCRIPTION

 

 

Radio frequency RF receiver (433.92 Mhz). 

Personal code on each product. 

Equipped with a push 

 

button to select 

AUTO

MANUAL 

or 

RF INIT

 

mode. 

To be used only with ours thermostats. 

 

RADIO CONFIGURATION MODE

 

 

1.  Install  and  plug the  Receiver. Then press  the Receiver  push  button        during  4 

seconds, the Green LED should lit up indicating that the Receiver is now in radio 
configuration mode waiting for a thermostat configuration address. 

 

2.  Please refer to the thermostat leaflet for enter 

the thermostat in “RF Init” mode. 

 

3.    Verify that radio signals are correctly received by the Receiver. On the Receiver, 

the Green LED should blink at each radio signal received from the thermostat. 

 

4.  Exit  the   Radio   configuration   mode   on   the   thermostat.  (Please   refer   to   the 

thermostat leaflet) 

 

5.    Now starting up your installation in AUTO mode. 

 

LED INDICATOR

 

 

 

Mode push button

 

 

 
 

AUTO Mode

 

 

Press 

button

 

 

Manual Mode

 

(Heater forced)

 

 

Press 

button

 

 

Manual Mode

 

(Stop forced)

 

 
 
 
 
 
 
 
 
 
 
 

 

Press 

button 

during 4sec

 

 
 
 
 
 
 
 
 
 
 

Manual Mode LED. 
(Yellow)

 

 

 
 
 
 
 
 
 
 
 

RF LED. 
(Green)

 

 

 
 
 
 
 
 
 

TECHNICAL CHARACTERISTICS

 

 

Press 

button 

RF init

 

Heating LED. 
(Red)

 

 

Press 

button

 

 

 
 
 

PPL IMP 2107B 