manualshive.com logo in svg
background image

 

 

 

 

 

 

Heating and Hot Water Solutions 

AERCO International, Inc.  •  100 Oritani Drive • Blauvelt, NY 10913

 

USA: T: (845) 580-

8000 • Toll Free: (800) 526

-

0288 • AERCO.com

 

Technical Support • (800) 526

-

0288 • Mon

-Fri, 8 am - 5 pm EST 

© 2020 AERCO 

Electrical Power Design Guide 

Other documents for this product include: 

OMM-0127, GF-205-K BMK750K-3000K Installation-Startup KOREA 
OMM-0128, GF-206-K BMK750K-3000K Operation- Maintenance KOREA 
OMM-0136, GF-210 BMK750-6000 Platinum-Edge Installation-Startup 
OMM-0137, GF-211 BMK750-6000 Platinum-Edge Operation-Service  
OMM-0138, GF-212 BMK750-6000 Platinum-Edge Reference Manual 
 
TAG-0019, GF-2070 Benchmark Boiler Application Guide 
TAG-0022, GF-2050 Benchmark Vent & Combustion Air Guide  
TAG-0047, GF-2030 Benchmark Gas Guide 
 
 

TAG-0048_P    

   GF-2060   

   8/6/2020 

Benchmark

®

 and Benchmark 

Platinum Boilers

 

Models 750 through 6000 

 

Disclaimer 

The information contained in this manual is subject to change without notice 
from AERCO International, Inc. AERCO makes no warranty of any kind with 
respect to this material, including, but not limited to, implied warranties of 
merchantability and fitness for a particular application. AERCO International is 
not liable for errors appearing in this manual, not for incidental or 
consequential damages occurring in connection with the furnishing, 
performance, or use of these materials. 

 

Содержание Aerco BMK 750

Страница 1: ...atinum Edge Reference Manual TAG 0019 GF 2070 Benchmark Boiler Application Guide TAG 0022 GF 2050 Benchmark Vent Combustion Air Guide TAG 0047 GF 2030 Benchmark Gas Guide TAG 0048_P GF 2060 8 6 2020 B...

Страница 2: ...hould be considered and installed whenever necessary 2 Boiler Electrical Requirements Benchmark boilers are available with the following power options BMK Model Voltage Phase Amperage BMK750 1000 Dome...

Страница 3: ...Support 800 526 0288 Mon Fri 8 am 5 pm EST Page 3 of 12 Figure 1 Service Disconnect Switch Typical Location Figure 2a Power Box Components BMK750 1000 DOMESTIC TERMINAL BLOCKS FUSE BLOCKS 12V POWER SU...

Страница 4: ...NAL Figure 3a Power Box Components BMK1500 2000 DOMESTIC TERMINAL BLOCKS FUSE BLOCKS POWER BREAKER 12V POWER SUPPLY TERMINAL BLOCKS POWER BREAKER FUSE BLOCKS 12 V POWER SUPPLY TRANSFORMER FLAME ROD SI...

Страница 5: ...2000 INTERNATIONAL Figure 4a Power Box Components BMK2500 6000 DOMESTIC POWER BREAKER FUSE BLOCKS 12V POWER SUPPLY TRANSFORMER 24 VDC POWER SUPPLY FLAME ROD SIGNAL AMPLIFIER TERMINAL BLOCKS 12 V POWER...

Страница 6: ...ace of the boiler or where they would interfere with the removal of the side or top panels for maintenance The service disconnect switch should be mounted near the unit as illustrated in Diagram 1 Wir...

Страница 7: ...the unit it only disables it Under no circumstance should the remote interlock of the BST Manager unit be used as an emergency switch for the plant The following table lists the input power requireme...

Страница 8: ...ST Page 8 of 12 Diagram 1b BMK750 2000 220 V 1 50 60 Hz Wiring Schematic 3 Wire INTERNATIONAL Diagram 2 BMK2500 3000 208 V 3 60 Hz Wiring Schematic 5 Wire DOMESTIC Diagram 3a BMK2500 5000N 480 V 3 60...

Страница 9: ...iagram 3b BMK2500 5000N 380 415 V 3 50 60 Hz Wiring Schematic 4 Wire INTERNATIONAL Diagram 4 BMK5000 6000 208 V 3 60 Hz Wiring Schematic 4 Wire DOMESTIC Diagram 5a BMK5000 6000 480 V or 575 V 3 60 Hz...

Страница 10: ...atic 4 Wire INTERNATIONAL Diagram 6a BMK4000 5000N 480 V 3 60 Hz Wiring Schematic 4 Wire DOMESTIC Diagram 6b BMK4000 5000N 380 415 V 3 50 60 Hz Wiring Schematic 4 Wire DOMESTIC 480 V 3 60 Hz 3 POLE 20...

Страница 11: ...matic 4 Wire DOMESTIC 5 Multiple Unit Wiring Whenever multiple units are installed within the same mechanical spaces electrical code requirements call for a single electrical shutoff for emergency use...

Страница 12: ...hange Log Date Description Changed by 6 9 2020 Rev O Added BMK5000N information where applicable Linley Thobourne Chris Blair 8 6 2020 Rev P Added diagram and description of E Stop power shutoff switc...

Отзывы: