background image

Hot Water Temperature Control Valves

Size: 

1

2

", 

3

4

", 1" (15,  20, 25mm)

Installation Instructions

Valve should be installed and adjusted by a licensed contractor in accordance with 

local codes and ordinances. Further, this valve should be installed in a location where it 

is accessible for cleaning, service or adjustment.
1.  Close both the hot and cold water shutoff valves upstream nearest to the intended 

installation.

2. Bleed the remaining water from the system.
3.  Connect the water supply to valve as shown in Figure 1 or 2, depending on the 

application. Supply piping must be flushed clean before making connections to the 

valve.

IMPORTANT!:

  To prolong the life of the Model 1170-M2, L1170-M2, LF1170-M2 or 

LFL1170-M2 valve, it is recommended that it be trapped as shown: i.e. the hot water 

inlet to the 1170-M2 or LF1170-M2 valve should be 8" – 12" (200 – 305mm) below 

the hot water supply feed.
4.  Valve can be installed in any position. Note: the inlet hot supply is to be connected 

to the “H” side of the valve, the cold supply side to the “C” side and the mixed water 

outlet to the “M” side.

5.  Make sure union nuts are placed over tailpieces prior to  

soldering or threading to pipe.

6.  For valves with Quick-Connect tailpieces refer to “Quick- 

Connect Installation” instructions below.

Note:

 To prevent damage to valve from excessive heat during  

soldering, remove unions and gaskets from valve body prior to  

soldering.
7.  After soldering, flush piping and install valve using filter washer  

on hot and cold water inlet and fiber washer on the mixed  

water outlet.

8.  Start-up: Open cold water supply, then hot water supply.  

Inspect for leaks.

9.  Adjust temperature to desired setting (see Temperature  

Adjustment Section).

IS-1170-M2_L1170-M2

Series 1170, LF1170, L1170 and LFL1170

Quick-Connect Installation

1.  Mark pipe as shown.  

This is pipe insertion depth.

2. Clean pipe end.

1. Remove collet clip.

2. Depress collet.

3. Pull tubing from tailpiece.

3.  If using PEX tubing, insert pipe 

stiffener (provided) into end of pipe.

4.  Push tubing into tailpiece up to mark.

5. Insert collet clip.

  To Connect

  To Disconnect

PEX tubing only

Pipe Stiffener

Tail Piece

Mark

Collet clip

Collet depressed

1

1

/

2

 in. (38.1mm)

1

3

/

4

 in. (44.45mm)

1

7

/

8

 in. (47.63mm)

3

/

4

 in.Pipe (19.05mm)

1 in.Pipe (25.4mm)

LF1170-UT-M2

1170-QC-M2

Watts  

Vacuum Relief 

Valve

Watts  Temperature

 

Gauge

Cold

Cold

Cold

1170-M2, L1170-M2 

LF1170-M2 or LFL1170-M2

Tempered 

Hot

Hot 

to 

 

Appliances

Watts T&P  

Relief Valve

*8" – 12"

H
C

M

Domestic Hot Water Application

*Note:

  To prolong the life of the valve, it is recommended the 

valve be trapped as shown

  Devices tested to ASSE 1070 or ASSE 1069 such as Watts 

USG, LFUSG, L111, MMV or LFMMV should be used at 

fixture to prevent possible injury.

Figure 1
Domestic Hot Water Application

1

/

2

 in.Pipe (12.7mm)

Отзывы: