DSW-302 and DSW-302-347
Dual Circuit Wiring
DSW-301 and DSW-301-347 Wiring
Breakaway
tab
Optional neutral
terminals behind
breakaway tab
6" flying leads for
line, load, ground
and multi-way
connections
Optional Neutral Wiring
For applications requiring neutral wiring, remove
tab as shown to expose terminals for wiring.
Black
Load
Red
Black
Neutral
Neutral
(optional)
Line
Neutral
(optional)
Ground
Green
Green
Ground
Green
Green
Yellow
traveler
Yellow
Multi-Way
The Multi-Way capability is available on all models. Sensors can easily be
wired together for convenient control of a common load. When wiring this
way, only use 300 series sensors. Multi-Way in 300 series is not compatible
with prior sensor models.
The following princlples apply for Multi-Way:
•
All units can see each other’s push button events and respond accord-
ingly.
•
All units can see each other’s PIR trigger event. The response will be
determined by the Light Level setting and/or conditions of the space of
the detecting sensor.
•
The time delay for all units is defined by the unit with the smallest time
delay
Typical wiring
(DSW-301 or DSW-301-347 - up to 4 sensors)