Procedure
4. Use
+/-
keys to alter station address, in range from 1 to 125. (126 is the default station address)
5. Choose:
l
FINISH
to set station address
OR
l
NEXT
to enable/disable
PROFIBUS Communication
Procedure
6. Use
+/-
keys to enable/disable PROFIBUS communication
7.
FINISH
store choice.
15.2.3 PROFIBUS data exchange
PROFIBUS data exchange
Default address
126
PROFIBUS Ident
0x0E7D
GSD File:
WAMA0E7D.GSD
Config:
0x62, 0x5D (3 words out, 14 words in)
User parameter bytes:
6
15 INSTALLATION: PART 6 (SETTING UP THE PUMP (CONTROL SETTINGS))
149