32
Performance data
32.1
620RE, 620RE4 and 620R performance data
Pumping conditions
All performance figures in this operating instruction have been recorded against peak pipeline
pressures.
This pump is rated to 4 bar (58psi) peak pressure when fitted with a 620RE, 620RE4 or 620LG pumphead
using high-pressure tubing. However, it will generate in excess of 4 bar (58psi) peak pressure if the
pipeline is restricted. Where it is important that 4 bar (58psi) is not exceeded, pressure relief valves should
be installed in the pipeline.
Viscosity handling is maximised by using 4.0mm wall LoadSure elements with the 620RE and 620RE4
pumpheads.
Flow rates are normalised test values obtained using new tubing with the pumphead rotating clockwise
pumping water at 20C with negligible inlet and discharge pressures. Actual flow rates achieved may vary
because of changes in temperature, viscosity, inlet and discharge pressures, system configuration and
tubing performance against time. Flow rates may also vary due to normal manufacturing tolerances of
the tubing. These tolerances will make flow rate variance more pronounced at smaller bore sizes.
For precise and repeatable performance it is important to determine flow rates under operating
conditions for each new piece of tubing. 620R and 620L family pumpheads' flow rates are directly
proportional to rotor speed. If you wish to run the pump at a speed not shown in the tables below, flow
figures can be reached by dividing the maximum flow shown in the tables below by the maximum rpm
figure, and multiplying the result by your required speed in rpm.
In normal circumstances, rotor and tube life are maximised if the pumphead is run slowly, particularly
when pumping at high pressure. However, to maintain performance at pressures above 2 bar, avoid
running the pumphead below 50rpm. If low-flow, high-pressure operation is necessary, switching to a
smaller tube is recommended.
STA-PURE Series PCS, STA-PURE Series PFL and Marprene TM tubing are hard to compress when new.
When using tubing made of these materials, the first five pumphead revolutions should be at a speed of
10rpm or greater. If the pump is run slower, the safety system built into pump drive’s software may
cause it to stop and display an over-current error message.
Note
: Flow rates quoted have been rounded for simplicity, but are accurate to within 5% - well within the
normal tubing tolerance variation of flow rate. They should therefore be taken as a guide. Real flow rates
in any application must be determined empirically.
620RE, 620RE4 and 620R flow rates - Metric (SI)
630 STA-PURE Series PCS, STA-PURE Series PFL, Neoprene, l/min
620R
620RE
620RE4
Speed
rpm
6.4mm
9.6mm
12.7mm
15.9mm
12.0mm
17.0mm
12.0mm
17.0mm
0.1
0.001
0.003
0.004
0.01
0.004
0.01
0.003
0.01
180
m-630un-en-08
Содержание 630 U
Страница 21: ...1 2 m 630un en 08 21 ...
Страница 62: ...14 7 Network topology Star network Ring network 62 m 630un en 08 ...
Страница 126: ...23 5 Flow Sensor Reading The flow sensor value can be read via the Flow sensor reading screen 126 m 630un en 08 ...
Страница 128: ...Press SELECT to choose an option Press EXIT to return to the screen from where the MENU was called 128 m 630un en 08 ...
Страница 158: ...Press HOME to return and store the setting The input is now enabled in manual mode 158 m 630un en 08 ...
Страница 159: ...25 Help 25 1 Help Select Help from the main menu to access the help screens m 630un en 08 159 ...
Страница 179: ...Number Spare Description 8 TT0005 10mm 3 8in spanner 9 MRA3026A Track assembly m 630un en 08 179 ...