background image

Watson-Marlow 323E, 323S, 323U and 323Du User Manual

1

WATSON-MARLOW BREDEL MANUALS

Watson-Marlow 323E, 323S,
323U and 323Du pumps

m-323e-s-u-du-gb-06

Contents

1

Declaration of conformity

2

2

Declaration of incorporation

2

3

Two-year warranty

3

4

When you unpack your pump

4

5

Information for returning pumps

5

6

Peristaltic pumps: an overview

6

7

Safety notes

7

8

Pump specifications

9

8.1

Pump features

9

8.2

Dimensions

14

9

Good pump installation practice 15
9.1

General recommendations 15

9.2

Do’s and do not’s

16

10 Connecting this product to a 

power supply

17

11 Start-up check list

18

12 Switching the pump on 

18

13 Auto-restart facility

19

14 Manual operation

20

15 Keypad lock

21

16 MemoDose

22

17 Automatic operation with

analogue signals, remote
control or RS232 link

23

17.1

Analogue signals and
remote control

24

17.2

Automatic control wiring 
using the 720N module

26

18 Care and maintenance

28

19 Troubleshooting

28

19.1

Error messages

29

20 Drive maintenance

30

21 Drive part numbers

30

22 Drive spares

31

23 Pumpheads

32

23.1

Pumpheads: key safety
information

32

23.2

313D and 314D 
pumpheads

32

23.3

313D and 314D 
pumphead order codes

34

23.4

313D and 314D flow rates 35

23.5

313D and 314D: 
maximum number of
pumpheads

36

23.6

313D and 314D: 
tubing part numbers

37

23.7

314MC and 318MC
microcassette pumpheads 38

23.8

314MC and 318MC
microcassette pumphead 
spares

40

23.9

314MC and 318MC
flow rates

41

23.10 314MC and 318MC

tubing part numbers

42

23.11 501RL pumphead

43

23.12 501RL and 501RL2 

installation

43

23.13 501RL and 501RL2 

tube loading

43

23.14 501RL and 501RL2 

rotor settings

44

23.15 501RL and 501RL2 

pumphead spares

45

23.16 501RL and 501RL2 

flow rates

46

23.17 501RL and 501RL2 

tubing part numbers

46

24 Trademarks

47

25 Warning not to use pumps in

patient-connected applications

47

26 Publication history

47

27 Decontamination certificate

48

Содержание 323S

Страница 1: ...ic control wiring using the 720N module 26 18 Care and maintenance 28 19 Troubleshooting 28 19 1 Error messages 29 20 Drive maintenance 30 21 Drive part numbers 30 22 Drive spares 31 23 Pumpheads 32 2...

Страница 2: ...not be put into service until the relevant machin ery has been declared in conformity with the Machinery Directive 2006 42 EC Responsible person Christopher Gadsden Managing Director Watson Marlow Lim...

Страница 3: ...itions of and specific exceptions to the above warranty are Conditions Products must be returned by pre arrangement carriage paid to Watson Mar low or a Watson Marlow approved service centre All repai...

Страница 4: ...323U and 323Du pumps are supplied as Dedicated 323E 323S 323U or 323Du pump drive unit fitted with one or more 313 or 314 pumpheads see 8 Pump specifications The designated mains power lead for your...

Страница 5: ...turned to Watson Marlow or its distributor A certificate included at the rear of these operating instructions or signed statement must be attached to the outside of the shipping carton This certificat...

Страница 6: ...first roller leaves the track the second continues to advance expelling the packet of fluid through the pump s discharge port At the same time a new partial vacuum is created behind the second roller...

Страница 7: ...t under the terms of the EU Waste Electrical and Electronic Equipment WEEE Di rective Fundamental work with regard to lifting trans portation installation starting up maintenance and repair should be...

Страница 8: ...d only for its intended purpose The pump must be accessible at all times to facilitate operation and maintenance Access points must not be ob structed or blocked The pump s mains plug is the disconnec...

Страница 9: ...control Backlight Beeper Manual screen rpm 15 400 rpm 27 1 speed control 3 400 rpm 133 1 speed control 1 5 220 rpm 147 1 speed control 5 rpm scrolling increment 1 rpm scrolling increment Auto restart...

Страница 10: ...t ted with a short nosed gearbox offers 15 400 rpm and can be fitted with a 313 or 314 pumphead The 323S 323U and 323Du are available with a choice of gearboxes a short nosed gearbox which offers 3 40...

Страница 11: ...against water projected from a nozzle against the equipment enclosure from any direction There must be no harmful effect water jet 12 Indoor use to provide a degree of protection against dust falling...

Страница 12: ...A Full load current 0 43A at 230V 0 86A at 115V Eprom version Accessible through pump software Enclosure rating IP31 to BS EN 60529 Equivalent to NEMA 2 Suitable for indoor use Pro tected against drip...

Страница 13: ...2 Class A called by BS EN 61000 6 4 Electrostatic discharge BS EN 61000 4 2 Radiated RF immunity BS EN 61000 4 3 A1 and A2 called by BS EN 61000 6 2 Fast transient burst BS EN 61000 4 4 A1 and A2 Leve...

Страница 14: ...S 323U and 323Du User Manual 14 8 2 Dimensions in millimetres 323E D 323S D 323U D 323Du D 323S MC 323U MC 323Du MC 323S RL 323U RL 323Du RL Drive only 313 501RL 323 4 2kg 9lb 4oz 4 5kg 9lb 14oz 5 5kg...

Страница 15: ...e local emergency stop device is fitted into the mains supply to the pump Valves Peristaltic pumps are self priming and self sealing against backflow No valves are required in inlet or discharge lines...

Страница 16: ...p is running Do ensure that on longer tube runs at least 1m of smooth bore flexible tubing is con nected to the inlet and discharge port of the pumphead to help to minimize impulse losses and pulsatio...

Страница 17: ...mains borne noise The voltage selector is mounted in the switchplate at the rear of the pump Set the voltage selector to 115V for 100 120V 50 60Hz supplies or 230V for 200 240V 50 60Hz supplies Al wa...

Страница 18: ...has been made to a suitable power supply Ensure that the recommendations in section 9 Good pump installation practice are followed Check the position of the voltage selector switch Check the mains po...

Страница 19: ...Mains power must be available to the pump to engage auto restart Stop the pump Turn off the mains power switch at the rear of the pump Hold down the START key and turn the mains power switch on The s...

Страница 20: ...irection is shown by the rotation symbol The di rection may be changed while the pump is stopped or running Start the pump with the START key The rotation symbol will move to confirm that the pump is...

Страница 21: ...o lock the keypad The padlock symbol will show and only the START and STOP key will function The keypad may also be locked while the pump is stopped Hold down the STOP key for more than 2 seconds The...

Страница 22: ...ispensed If the quantity is correct press START to repeat the dose If the initial dose is larger than required use the DOWN key to reduce the volume showing on the display This will reduce the next do...

Страница 23: ...ump speed Check that the pump is ready to run before selecting automatic operation Remote control signals may start the pump without warning Press the MODE key to select automatic operation The pump w...

Страница 24: ...rror message E21 Over signal See 19 Error messages The remote stop start input works with both manual and analogue control modes The remote direction input works only with analogue control mode Never...

Страница 25: ...remote stop start switch If you invert the operation of the remote stop start switch you must connect a wire link from pin 7 to 17 to be able to start the pump from the keypad This diagram shows the c...

Страница 26: ...17 2 RS232 serial link The RS232 interface will give basic pump control by serial link to the 9 way D con nector at the rear of the pump To select RS232 serial control repeat MODE key press until dig...

Страница 27: ...unction 1SPxxx Set pump speed to xxx 1RC Reverse direction 1SI Increase speed by 1rpm 1RR Set clockwise direction 1SD Reduce speed by 1rpm 1RL Set counter clockwise direction 1GO Start pump 1RS Show a...

Страница 28: ...n Marlow or its appointed agents or distributors for service 19 Troubleshooting If the pump display remains blank when the pump is on make the following checks Check the position of the voltage select...

Страница 29: ...upport 15 Over current Stop pump immediately Check system Power OFF ON may reset Or seek support 16 Over voltage Stop pump immediately Check mains voltage se lector switch Check supply Power OFF ON ma...

Страница 30: ...00U 323S 220 N A UK 036 3134 00U 323S 400 N A UK 036 3142 00U 323U 220 N A UK 036 3144 00U 323U 400 N A UK 036 3152 00U 323Du 220 N A UK 036 3154 00U 323Du 400 N A UK Complete pump assemblies Part nu...

Страница 31: ...al 31 E S U Du 22 Drive spares Spare Description 1 MNA2042A 313 and MC bayo net mounting plate 400 rpm models only 2 MN2056M E and S interface card cover 3 MN2094T U interface card cover 4 MN2095T Du...

Страница 32: ...and is designed to provide higher flow rates The 314D pumphead has four rollers to provide greater pumping precision with less pulsation in the flow Both designs are available for 1 6mm and 2 4mm wal...

Страница 33: ...n the pumphead clockwise until it locks into an upright position Removal Push the locking lever back and turn the pumphead anti clockwise until it is free from the mounting plate Tube loading Switch o...

Страница 34: ...to resettle naturally across the rollers Re clamp the tube Re start the pump This will correct the normal stretching that occurs with new Marprene tube The correct tension is essential for good tube...

Страница 35: ...rpm 1 5 220 rpm 0 45 12 0 09 12 0 05 6 6 1 1 28 0 21 28 0 11 15 4 1 110 0 81 110 0 41 59 15 400 3 0 400 1 5 220 33 880 6 6 880 3 3 480 54 1400 11 1400 5 4 790 75 2000 15 2000 7 5 1100 Flow rates 314D...

Страница 36: ...Tygon Neoprene Fluorel 0 2 bar bore mm 0 5 0 8 1 6 3 2 4 8 6 4 8 0 in 1 50 1 32 1 16 1 8 3 16 1 14 5 16 112 13 14 16 25 17 18 220 400 rpm 6 6 4 2 2 1 1 313D 314D STA PURE CHEM SURE 0 5 2 bar bore mm 1...

Страница 37: ...903 0080 016 965 0080 016 913 A080 016 1 6mm tube mm in PVC Fluorel Neoprene STA PURE 0 8 1 32 13 920 0008 016 1 6 1 16 14 950 0016 016 970 0016 016 920 0016 016 960 A016 016 3 2 1 8 16 950 0032 016 9...

Страница 38: ...design Cassettes locate quickly with a single cam lever action that also controls roller pressure against the tube Extension pumpheads may be added up to 10 channels All are bayonet mounted for easy...

Страница 39: ...the cassette legs Slide the tubing evenly down into the slots Do not twist the tube or use unnecessary force Slip the collars past the retaining fingers and ensure the tubing has reached the bottom of...

Страница 40: ...d spares Spare Description 1 033 6453 000 314MC four roller five channel pumphead 1 033 6454 000 314MCX four roller five channel extension pumphead 1 033 6853 000 318MC eight roller five channel pumph...

Страница 41: ...35 1 8 13 yellow yellow 1 42mm 0 055in 0 46 2 3 17 yellow blue 1 52mm 0 060in 0 52 2 6 19 blue blue 1 65mm 0 065in 0 60 3 0 22 green green 1 85mm 0 070in 0 76 3 8 28 purple purple 2 05mm 0 080in 0 90...

Страница 42: ...0 050in 979 0129 000 981 0129 000 983 0129 000 yellow yellow 1 42mm 0 055in 979 0142 000 981 0142 000 983 0142 000 yellow blue 1 52mm 0 060in 979 0152 000 981 0152 000 983 0152 000 blue blue 1 65mm 0...

Страница 43: ...a drive pin inside the rotor collet to engage with the end of the drive shaft To keep this pin correctly engaged on the drive shaft we recommend that the collet remains on the shaft while the rotor i...

Страница 44: ...e clamp at the outlet of the pump Pull any slack tube from the pumphead and re clamp the tube Re start the pump This will correct the normal stretching that oc curs with new Marprene tube The correct...

Страница 45: ...ad 053 0001 L20 501RL2 complete pumphead 1 SG001 SG002 Springs for 501RL blue Springs for 501RL2 red 2 MN0012T Follower roller 3 MN0011T Main roller 4 MNA0143A 501RL rotor assembly 5 CL0656T Collet 6...

Страница 46: ...016 965 0016 016 913 A016 016 3 2 1 8 16 902 0032 016 903 0032 016 965 0032 016 913 A032 016 4 8 3 16 25 902 0048 016 903 0048 016 965 0048 016 913 A048 016 6 4 1 4 17 902 0064 016 903 0064 016 965 0...

Страница 47: ...a Pure and Chem Sure are trademarks of W L Gore and Associates 25 Warning not to use pumps in patient connected applications Warning These products are not designed for use in and should not be used f...

Страница 48: ...contamination certificate for each product You are responsible for cleaning and decontaminating the product s before return Your name Company Address Postcode zip Country Telephone Fax Product type Se...

Отзывы: