1.10
Power supply
The 120 pump is suitable for single-phase mains electricity supplies only via the double-insulated (Class II)
90– 264VAC to 24VDC mains adaptor. Use only the approved 24VDC Meanwell type GE24I24-P1JK DC
adaptor or thePowersolve ESA24-24DC adaptor supplied with thepump.
A well regulated electrical mains supply is required along with cable connections conforming to the best
practice of noise immunity. It is not recommended to site these drives alongside “dirty” electrical mains
supplies such as 3-phase contactors and inductive heaters without special attention being paid to
unacceptable mains-borne noise.
Power supply specifications
Insulation category
Class II: double insulated, no earth
Mains
voltage/frequency
90-264VAC, 47-63Hz, 1ph
Mains current
0.7A @ 100VAC; 0.4A @ 230VAC
Output voltage
24VDC
Output power
24W @ 30C; 18W @ 40C
Protection
Hiccup mode: recovers automatically after fault removed
Overload protection
110%-200% of rated output power
Working temperature
-10C to 50C, 14F to 122F
Operating humidity
20% to 90% RH, non-condensing
Over-voltage
115% to 135%
We recommend using commercially available supply voltage surge
suppression where there is excessive electrical noise.
m-120-en-02