9. Materials of construction: 
800 series ATEX pumpheads

Description

Part No, 825 Part No, 840

Material

Finish

Track

HFZ8013C

Aluminium LM25TF

paint

Door

HF1264C

HF1402C

Aluminium LM25TF

paint

Window

HF1005S

HF1005S

PVC

Pin - hinge

HF1007T

HF1107T

Stainless steel 303S31

Spacer - hinge pin

HF1224T

HF1224T

Nylatron GS

Tube clamp, static

HF1211T

HF1411T

Aluminium HE30

Tube clamp, dynamic

HF1212T

HF1412T

Aluminium HE30

Pin - tube clamp

HF1213T

HF1413T

Stainless steel 303S31

Insert - tube clamp

HF1228T

HF1428T

Stainless steel 303S31

Rotor

HF1203C

HF1403C

Aluminium LM25TF

Paint

Plate - rotor clamp

HF1244T

HF1421T

Stainless steel 303S31

Spacer - rocker

HF1208T

HF1408T

Nylatron GS

Pin - rotor pivot

HF1210T

HF1410T

Stainless steel 303S31

Spacer - pivot pin

HF1225T

HF1408T

Nylatron GS

Spring - rotor torsion

HF1237B

HF1437B

Stainless steel 302 AMS5688

Rocker

HF1204C

HF1404C

Aluminium LM25TF

paint

Plate - rocker side 1

HF1219S

HF1419S

Stainless steel 304S31

Plate - rocker side 2

HF1220S

HF1424S

Stainless steel 304S31

Spacer - rocker

HF1223T

HF1423T

Stainless steel 303S31

Rollers

HF1216T

HF1416T

Stainless steel 316S16

Bearing - ball

BB0044

BB0047

Steel (1%C; 1.5%Cr)

Spindle - roller

HF1217T

HF1417T

Stainless steel 316S16

Seal - shaft

OS0038

OS0041

NBR/Stainless steel

Spring

SG0013

SG0015

Stainless steel 

passivate

Pedestal - gearbox

HF1242S

HF1242S

Stainless steel 304S11

Frame - support

HF1271S
HF1272S

HF1467S
HF1468S

Stainless steel 304S11

Switch - door 
(ATEX rated)

SWZ8002

SWZ8002

The above materials have been carefully selected and have a well proven track record.
However, if there are any aggressive chemicals present then it is imperative that a risk
assessment is conducted. This must not be limited to just the pumped fluid but should
also include any other aggressive fluids in the intended operating environment.

Содержание 800 Series

Страница 1: ...94 9 EC commonly known as the ATEX directive carries obligations to the person who places equipment on the market in the EU territory for use in potentially explosive environments A number of pumps ma...

Страница 2: ...ir intended use in areas in which explosive atmospheres caused by mixtures of air and gases vapours mists or air dust mixtures are likely to occur Watson Marlow s ATEX pumps are rated for use in gas b...

Страница 3: ...e values must not be exceeded ATEX compliance will be invalidated 800 series ATEX pumps Operational temperature range 20C to 40C ambient Max peak pressure 3 5 bar WARNING Do not run pumphead against a...

Страница 4: ...ion to engineering modifications the changes include additional operating instructions in order to specifiy correct usage in hazardous locations Please refer to Sections 6 10 for further details Recog...

Страница 5: ...watson marlow com wmb gb p chem a htm Immersion kits are available from Watson Marlow for testing For each application it is strongly recommended that tube life should be determined by trials prior t...

Страница 6: ...e pumphead out with water and mild detergent as soon as possible If specific cleaning agents are required to clean the spillage please consult the Watson Marlow after sales office before proceeding in...

Страница 7: ...atron GS Spring rotor torsion HF1237B HF1437B Stainless steel 302 AMS5688 Rocker HF1204C HF1404C Aluminium LM25TF paint Plate rocker side 1 HF1219S HF1419S Stainless steel 304S31 Plate rocker side 2 H...

Страница 8: ...EX manual This is an addendum to the existing manual and includes ATEX specific information ATEX rated door switch Standard 825 and 840 pumps are supplied with EExd switches These are upgraded to ATEX...

Страница 9: ...order to guarentee continued compliance with the ATEX Directive Watson Marlow s policy is to provide spare parts for all products for a minimum of seven years from discontinuation The ability to impl...

Страница 10: ...ATEX Directive Watson Marlow 800 series pumps and pumpheads User Manual 10 13 Manufacturer s Declaration...

Отзывы: