ATEX Directive: Watson-Marlow 800 series pumps and pumpheads User Manual

5

Where there is potential for the pumped fluid to become charged through pumping,
protective measures should be implemented at the discharge outlet to dissipate this
charge safely.

It is recommended that the chosen ATEX drive (motor/gearbox) is configured to safely
reach an overload condition before the 135Nm torque limit is reached. This 
will prevent catastrophic mechanical failure in the rare occurrence of a major 
obstruction.

Note

: Tube contact with polyamide materials such as nylon should be avoided.

7. Tube life

Only Watson-Marlow tubing should be used to guarantee continued compliance with
the ATEX directive.

A number of factors contribute to the life of the tubing:

Factors influencing tube life

Normal tube fatigue - dependent on tube size, material and 
pumphead speed

Incorrect tube loading - see the 800 series manual 
(800-gb-01.pdf) for guidance

Excess working pressure - see Section 4 Operating parameters

Chemical incompatibility - a table of tubing compatibility can be
found on http://www.watson-marlow.com/wmb-gb/p-chem-a.htm.
Immersion kits are available from Watson-Marlow for testing.

For each application it is strongly recommended that tube life should be determined
by trials, prior to installation in a hazardous environment. If this is not possible, 
or if there is any doubt in terms of tube life then the following hazards should be
recognised before installing a pump in a potentially explosive atmosphere: 

Chemical reaction between spilled pumped fluid and pump 
materials - the materials of construction are listed in Section 9

Spilled, pumped fluid could be ignited by the surface temperature
of the rollers - Watson Marlow’s 800 series pumpheads have been
rated as T4 (meaning that even under worst-case operating 
conditions the maximum surface temperature will not exceed
135C)

WARNING: The tube connectors are isolated metal parts and have no
path to earth via the pumphead. 800 series ATEX pumps are designed to
be connected into conductive metal piping systems, where static charge
on the tube connectors is dissipated via the pipe system earthing
arrangement. If the pump is used in a system with non-conductive pipes
or connections, the user will need to make provision for earthing the
tube connectors to ensure dissipation of any static charge.

Содержание 800 Series

Страница 1: ...94 9 EC commonly known as the ATEX directive carries obligations to the person who places equipment on the market in the EU territory for use in potentially explosive environments A number of pumps ma...

Страница 2: ...ir intended use in areas in which explosive atmospheres caused by mixtures of air and gases vapours mists or air dust mixtures are likely to occur Watson Marlow s ATEX pumps are rated for use in gas b...

Страница 3: ...e values must not be exceeded ATEX compliance will be invalidated 800 series ATEX pumps Operational temperature range 20C to 40C ambient Max peak pressure 3 5 bar WARNING Do not run pumphead against a...

Страница 4: ...ion to engineering modifications the changes include additional operating instructions in order to specifiy correct usage in hazardous locations Please refer to Sections 6 10 for further details Recog...

Страница 5: ...watson marlow com wmb gb p chem a htm Immersion kits are available from Watson Marlow for testing For each application it is strongly recommended that tube life should be determined by trials prior t...

Страница 6: ...e pumphead out with water and mild detergent as soon as possible If specific cleaning agents are required to clean the spillage please consult the Watson Marlow after sales office before proceeding in...

Страница 7: ...atron GS Spring rotor torsion HF1237B HF1437B Stainless steel 302 AMS5688 Rocker HF1204C HF1404C Aluminium LM25TF paint Plate rocker side 1 HF1219S HF1419S Stainless steel 304S31 Plate rocker side 2 H...

Страница 8: ...EX manual This is an addendum to the existing manual and includes ATEX specific information ATEX rated door switch Standard 825 and 840 pumps are supplied with EExd switches These are upgraded to ATEX...

Страница 9: ...order to guarentee continued compliance with the ATEX Directive Watson Marlow s policy is to provide spare parts for all products for a minimum of seven years from discontinuation The ability to impl...

Страница 10: ...ATEX Directive Watson Marlow 800 series pumps and pumpheads User Manual 10 13 Manufacturer s Declaration...

Отзывы: