IP66 pumps are supplied with a mains plug. The gland at the NEMA Module
end of the cable is IP66 rated. The mains plug at the opposite end of the cable
is NOT IP66 rated. It is your responsibility to ensure that the connection to the
mains supply is IP66 rated.
10.1
Conductor colour coding
Table 3 - Conductor colour coding
Conductor type
European colour
North American colour
Line
Brown
Black
Neutral
Blue
White
Ground
Green/Yellow
Green
10.2
Wiring the NEMA module - EtherNet/IP™ pumps
The NEMA 4X modules fitted to 530, 630 and 730 EnN cased pumps have two pairs of wiring ports.
Two M16 ports are provided, together with glands to seal circular cross-section cables ranging in
diameter from 4 mm to 10 mm (5/32 in to 13/32 in.) Ethernet connection is via the two M12
connectors mounted to the rear of the NEMA module.
Figure 10 - Earth screening of control cables onEtherNet/IP™ NEMA module
1
Control cable earth screening connected to Earth terminal (J6) on adapter PCB when plastic cable
gland is used.
m-730en-en-09 02-02-22
19