Param No.
Signal
Offset
Type
11
ResetFlowTotaliser
16
BOOL
12
ResetRevolutionCount
17
BOOL
EDS compatibility guide
EDS file
name
(Found on
website)
EDS
release
Date
Pump
Models
Compatible
with pump
software
versions
Version comments
5/6/730
EtherNet/IP™
EDS Rev 2.1
March
2020
530En,
630En,
730En
0.26.02
Initial EDS release
5/6/730
EtherNet/IP™
EDS Rev 2.2
November
2020
530En,
630En,
730En
0.27.04
Addition of asset number (parameter 63),
Error Acknowledge (parameter 64), RPI range
(parameter 65), parameter re-ordering
Link to EDS file location:
https://www.watson-marlow.com/gb-en/literature/?model=EDS
Notes:
1.
If your pump software is compatible with multiple EDS files versions it is recommended to use the
latest version available.
2.
In order to find your pump software version, select 'Help', then 'Software' on your pump
3.
The correct EDS file version must be used in combination with the pump software versions listed
for good communication between the pump and control system.
4.
Networks using pumps with different software and EDS versions are acceptable as long as each
pump is using the correct EDS version
19.7
Pump parameters
Setting parameters
To set a parameter to a new value:
•
Type a value into the field or click on the check box (depending on the parameter type).
•
Click 'set' to store the new value or click 'refresh' to cancel the change.
•
Up to 100 parameters are displayed per page. Use the < and > buttons to navigate between
pages.
54
m-730en-en-08.1