Watson Marlow Pumps 603R Скачать руководство пользователя страница 2

 

2

 

Declarations 

 

Declaration of 
conformity

  

 

When this pump unit is used as a stand alone pump it complies with: Machinery 
Directive 98/37/EC EN60204-1, Low Voltage Directive 73/23/EEC EN61010-1, EMC 
Directive 89/336/EEC, EN50081-1/EN50082-1. 

 

Declaration of 
Incorporation

 

When this pump unit is to be installed into a machine or is to be assembled with other 
machines for installations, it must not be put into service until the relevant machinery 
has been declared in conformity with the Machinery Directive 98/37/EC  EN60204-1.

 

 
Responsible person: Dr R Woods, Managing Director, Watson-Marlow Limited, Falmouth, Cornwall TR11 4RU, 
England. Telephone 01326 370370  Fax  01326 376009. 

 

Two year warranty 

Watson-Marlow Limited warrants, subject to the conditions below, through either Watson-Marlow Limited, its 
subsidiaries, or its authorised distributors, to repair or replace free of charge, including labour, any part of this product 
which fails within two years of delivery of the product to the end user. Such failure must have occurred because of 
defect in material or workmanship and not as a result of operation of the product other than in accordance with the 
instructions given in this manual. 

Conditions of and specific exceptions to the above warranty are: 

• 

Consumable items such as tubing and rollers are excluded. 

• 

Products must be returned by pre-arrangement carriage paid to Watson-Marlow Limited, its subsidiaries, or its 
authorised distributor. 

• 

All repairs or modifications must have been made by Watson-Marlow Limited, its subsidiaries, or its authorised 
distributors or with the express permission of Watson-Marlow Limited, its subsidiaries, or its authorised distributors. 

• 

Products which have been abused, misused, or subjected to malicious or accidental damage or electrical surge are 
excluded. 

Warranties purporting to be on behalf of Watson-Marlow Limited made by any person, including representatives of 
Watson-Marlow Limited, its subsidiaries, or its distributors, which do not accord with the terms of this warranty shall not 
be binding upon Watson-Marlow Limited unless expressly approved in writing by a Director or Manager of Watson-
Marlow  Limited. 

Information for returning pumps 

Equipment which has been contaminated with, or exposed to, body fluids, toxic chemicals or any other substance 
hazardous to health must be decontaminated before it is returned to Watson-Marlow or its distributor. 

A certificate included at the rear of these operating instructions, or signed statement, must be attached to the outside 
of the shipping carton. 

This certificate is required even if the pump is unused. If the pump has been used, the fluids that have been in contact 
with the pump and the cleaning procedure must be specified along with a statement that the equipment has been 
decontaminated. 

Safety 

In the interests of safety, this pump and the tubing selected should only be used by competent, suitably trained 
personnel after they have read and understood this manual, and considered any hazard involved. 

Any person who is involved in the installation or maintenance of this equipment should be fully competent to carry out 
the work. In the UK this person should also be familiar with the Health and Safety at Work Act 1974. 

 

 

There are dangerous voltages (at mains potential) inside the pump. If access is 
required, isolate the pump from the mains before removing the cover.

 

 

Содержание 603R

Страница 1: ...604U 604u gb 02 pdf...

Страница 2: ...ss permission of Watson Marlow Limited its subsidiaries or its authorised distributors Products which have been abused misused or subjected to malicious or accidental damage or electrical surge are ex...

Страница 3: ...s is to counteract the normal stretching that occurs with Marprene which can go unnoticed and result in poor tube life Tube selection The chemical compatibility list published in the Watson Marlow cat...

Страница 4: ...otation The preferred direction of rotation is clockwise with fluid entering at the bottom of the pumphead which will ensure the longest possible tube life To operate against higher pressures use anti...

Страница 5: ...l level which has to be reached in order for the pump rotor to start rotating Signal range is the change in process signal level necessary to produce the required change in pump rotor speed For exampl...

Страница 6: ...ld the motor to maximum speed at the MAX setting indicated by the LED indicator flashing If the signal rises above 30V permanent damage not covered by warranty may result Securely replace the rear pan...

Страница 7: ...55 Machinery Directive 98 37 EC EN60204 1 Low Voltage Directive 73 23 EEC EN61010 1 EMC Directive 89 336 EEC EN50081 1 EN50082 1 Specific drive performance details such as loaded drive speed variation...

Страница 8: ...track with the retaining screws Ensure the drive shaft has been completely degreased before locating the rotor onto the shaft via a split collet Tighten the rotor bolt to a torque of 13Nm to prevent t...

Страница 9: ...ot slack in the pumphead since this can reduce tube life Clamp the tube very firmly by turning the upper serrated adjustment wheel Remove the spanner and close the guard Roller adjustment Should it ev...

Страница 10: ...0258M Guard 3 SW 0139 Guard Switch magnet 4 MR 0601T Collet 5 MR 0571T Roller tube 6 MR 0575T Roller tube guide 7 MR 0573T Spindle 8 MRA0010A Rotor assembly 9 SG 0003 Spring 10 MR 0572T Roller guide...

Страница 11: ...Terminal block 5 UP 0035 6 pin plug 18 MR 0691S Gasket 6 US 0035 6 pin socket 19 OS 0042 Seal O ring 7 FA 0010 Earth filter 20 SW 0146 Auto man max 8 MR 0669S Cover plate 21 MR 0769B Potentiometer 9 M...

Страница 12: ...12 Outline dimensions...

Страница 13: ...ach pump returned RGA No 1 Company Address Postcode Telephone Fax Number 2 1 Serial Number One product per declaration 2 2 Has the Product been used Yes No If yes please complete all the following Sec...