8
Pump specifications
8.1
Specification ratings
Operating temperature
5 °C to 40 °C (41 °F to 104 °F)
Storage temperature
530: -40 °C to 70 °C (-40 °F to 158 °F)
Humidity (non-condensing)
80 % up to 31 °C (88 °F) decreasing linearly to 50 % at 40 °C (104 °F)
Maximum altitude
2000 m (6560 ft)
Power Rating
530: 135 VA
Supply voltage
100-120 V/200-240 V 50/60 Hz 1 pH (Subject to regional cord sets
and supply)
Maximum voltage fluctuation
+/-10 % of nominal voltage. A well regulated electrical mains supply
is required along with cable connections conforming to the best
practice of noise immunity.
Full load current
530: <0.6 A @ 230 V; <1.25 A @ 115 V
Fuse rating
T2.5AH250V (5x20 mm)
Installation category
(overvoltage category)
II
Pollution degree
2
IP
530: IP31 to BS EN 60529, if supplied with N module then IP66 to BS
EN 60529. Equivalent to NEMA 4X to NEMA 250 *(indoor use -
protect from prolonged UV exposure)
dB rating
530: < 70 dB (A) @ 1 m
Control ratio
530: 0.1-220 rpm (2200:1)
Maximum speed
530: 220 rpm
m-530dun-en-08.2
13