12.6
PROFINET® pump external interface parameters
Table 6 - External interface parameters
Parameter
Limits
Units
Comment
Sym
Min
Nom
Max
Digital input voltage high
VD
IH
5
24
V
Leak, Stop, PRESSURE_
ALARM, Frequency
Digital input voltage low
VD
IL
0
0.8
V
Leak, Stop, PRESSURE_
ALARM, Frequency
Digital input voltage absolute
maximum
VD
in
-30
30
V
Non operational
Digital input resistance
RD
in
10
110
kΩ
110K for ≤ 5 V
Frequency range
F
max
1
1000
Hz
Frequency
Repetition rate
F
max
1
10
Hz
Leak, Stop, Pressure
Analogue input, voltage mode
VA
in
-15
10
30
V
0-10 V range (100R
source impedance)
Analogue input, voltage mode RVA
in
34.4
kΩ
±3 %
Analogue input measurement
range
I
in
0
25
mA
Analogue input current
absolute maximum
IA
in
-50
28
mA
Dissipation limit
Analogue input voltage
absolute maximum
VA
in
0
7.0
V
Dissipation limit
Analogue input resistance
RI
IN
250
270
Ω
250R Sense Res.
Analogue input filter
bandwidth
BW
67
Hz
-6 dB Bandwidth
22 V supply output
V
aux
18
30
V
Un-regulated
24 V isolated supply output
V24
24
22 V/24 V supply load current
80
mA
Self-resetting fuse
32
m-530pn-en-09 02-02-22
Содержание 500 Series
Страница 33: ...12 7 Network topology Figure 17 Star network m 530pn en 09 02 02 22 33 ...
Страница 34: ...Figure 18 Ring network Figure 19 Line topology 34 m 530pn en 09 02 02 22 ...
Страница 71: ...3 Press HOME to return and store the setting The input is now enabled in Manual mode m 530pn en 09 02 02 22 71 ...
Страница 72: ...15 6 Help Help 1 Select Help from the main menu to access the help screens 72 m 530pn en 09 02 02 22 ...
Страница 81: ...1 Press the MODE key to access the MODE menu 2 Use the keys to select PROFINET m 530pn en 09 02 02 22 81 ...
Страница 84: ...4 Press BACK to return to the MODE MENU 84 m 530pn en 09 02 02 22 ...