PROFINET (Industrial Ethernet) connection
There are two communication connectors on the rear of the N Module for PROFINET (Industrial
Ethernet) connection (3,4). Both connectors have the same pin configuration. The pin configuration
and the signal response is shown below.
Plugs and cables for these connectors should be: M12, male, 4-Pin D coded, shielded.
1
2
3
4
TX+
RX+
RX-
TX-
Figure 14 - Ethernet connection
Adapter PCB
Figure 15 - Adapter PCB
1.
2.
U1
1.
Without isolated power supply option
(N Module)
2.
With isolated power supply option
(F Module)
Note: Disconnect the adapter module by use of the ribbon eject levers. It is recommended to leave
the 9W connector permanently attached to the pump.
Recommended control cable: metric = 0.05 sq mm - 1.31 sq mm solid and stranded. USA = 30AWG -
16AWG solid stranded. Cable: circular. Max/min outside diameter to ensure a seal when passed
through the standard gland: 9.5 mm-5 mm.
The cable section must be circular to ensure a seal
.
28
m-530pn-en-09 02-02-22
Содержание 500 Series
Страница 33: ...12 7 Network topology Figure 17 Star network m 530pn en 09 02 02 22 33 ...
Страница 34: ...Figure 18 Ring network Figure 19 Line topology 34 m 530pn en 09 02 02 22 ...
Страница 71: ...3 Press HOME to return and store the setting The input is now enabled in Manual mode m 530pn en 09 02 02 22 71 ...
Страница 72: ...15 6 Help Help 1 Select Help from the main menu to access the help screens 72 m 530pn en 09 02 02 22 ...
Страница 81: ...1 Press the MODE key to access the MODE menu 2 Use the keys to select PROFINET m 530pn en 09 02 02 22 81 ...
Страница 84: ...4 Press BACK to return to the MODE MENU 84 m 530pn en 09 02 02 22 ...