6 Recommended operating procedures

DO

keep delivery and suction lines as short as possible using a minimum number of swept bends.

DO

use suction and delivery pipelines with a bore equal to or larger than the bore of the tube fitted in

the pumphead.
When pumping viscous fluids, the losses caused by increased friction can be overcome by using pipe
runs with a cross sectional area several times greater than the pumping element.

DO

fit an extra length of pumphead tube in the system to enable tube transfer. This will extend tube life

and minimise the downtime of the pumping circuit.

DO

keep the track and rollers clean.

The self-priming nature of peristaltic pumps means valves are not required. Any valves fitted must
cause no restriction to flow in the pumping circuit.

Tube selection:

The chemical compatibility lists published on the Watson-Marlow website are guides.

If in doubt about the compatibility of a tube material and the duty fluid, request a Watson-Marlow tube
sample card for immersion trials.

m-505ca-en-01

9

Содержание 500 Series

Страница 1: ...m 505ca en 01 1 505CA pumphead user manual...

Страница 2: ...erating procedures 9 7 Pumphead installation 10 8 Fitting an extension pumphead 11 9 CA cassette loading 12 10 CA cassette removal 13 11 CA cassette adjustment and flow rates 14 12 Care and maintenanc...

Страница 3: ...2 Certification Certification documents follow on the next pages m 505ca en 01 3...

Страница 4: ...easoned request by the appropriate national authorities relevant information on the partly completed equipment identified above The method of transmission shall be by mail or email 7 The pumphead is i...

Страница 5: ...nd Electronic Equipment Regulations 2012 5 We undertake to transmit in response to a reasoned request by the appropriate national authorities relevant information on the partly completed equipment ide...

Страница 6: ...nience loss of product pumped and loss of production This warranty does not obligate Watson Marlow to bear any costs of removal installation transportation or other charges which may arise in connecti...

Страница 7: ...tion we will issue a Returns Authorisation Number We reserve the right to quarantine or refuse any equipment that is not displaying a Returns Authorisation Number Please complete a separate decontamin...

Страница 8: ...itably trained personnel after they have read and understood this manual and considered any hazard involved Any person who is involved in the installation or maintenance of this equipment should be fu...

Страница 9: ...e pumping element DO fit an extra length of pumphead tube in the system to enable tube transfer This will extend tube life and minimise the downtime of the pumping circuit DO keep the track and roller...

Страница 10: ...eaded screws provided 2 l Apply grease to the drive tongue 1 align to pumphead centre shaft and locate together l Remove the planetary gear system cover by pulling gently towards the front of the pump...

Страница 11: ...lanetary gear system cover from the extension pumphead l Fit the extension pumphead onto the two locating pins ensuring the tongue of its drive shaft aligns with the pumphead centre shaft l Tighten th...

Страница 12: ...stretching it 1 l Lift the cassette release lever 2 l Load the cassettes into the pumphead ensuring that they are engages on the to the cassette guides at each end 3 l Ensure that both retaining clips...

Страница 13: ...a single cassette can be removed for tube changing without stopping the drive and disturbing the pumping action of other cassettes All cassettes must be in position in the pumphead during normal runni...

Страница 14: ...n designed so that when the indicator is at the centre position it is indicating the normal set up l To adjust pull out the adjusting knob and turn To lock push back l Moving the indicator towards the...

Страница 15: ...settes from the pumphead and remove the tubing Wash the cassettes in water and mild detergent If fluid has been spilled into the pumphead removal of the pumphead from the drive will make cleaning easi...

Страница 16: ...ler 4 way Roller 8 way Roller 12 way Roller 16 way 4a BB 0038 2 off Center shaft bearing 4b BB 0014 2 off Center spacer bearing 5 DE 0429T Center gear 6 MN 0983M Roller gear 7 OS 0047 Friction O ring...

Страница 17: ...14 Dimensions Table 2 Dimensions Pumphead channels Dimension X 4 99 8 148 12 197 16 246 Figure 5 Dimensions m 505ca en 01 17...

Страница 18: ...18 m 505ca en 01 15 Publication history m 505ca en 01 First published 12 22...

Страница 19: ...s Figure 1 Pumphead installation 10 Figure 2 Extension pumphead installation 11 Figure 3 CA cassette loading 12 Figure 4 Pumphead spares 16 Figure 5 Dimensions 17 16 2 Tables Table 1 Pumphead spares 1...

Отзывы: