3 Warranty

Watson-Marlow Ltd ("Watson-Marlow") warrants this product to be free from defects in materials and workmanship for 1
year from the date of shipment, under normal use and service.
Watson-Marlow's sole responsibility and the customer's exclusive remedy for any claim arising out of the purchase of any
product from Watson-Marlow is, at Watson-Marlow's option: repair, replacement or credit, where applicable.
Unless otherwise agreed in writing, the foregoing warranty is limited to the country in which the product is sold.
No employee, agent or representative of Watson-Marlow has the authority to bind Watson-Marlow to any warranty other
than the foregoing unless in writing and signed by a director of Watson-Marlow. Watson-Marlow makes no warranty of
the fitness of its products for a particular purpose.
In no event:

i. shall the cost of the customer's exclusive remedy exceed the purchase price of the product;

ii. shall Watson-Marlow be liable for any special, indirect, incidental, consequential, or exemplary damages, however

arising, even if Watson-Marlow has been advised of the possibility of such damages.

Watson-Marlow shall not be liable for any loss, damage, or expense directly or indirectly related to or arising out of the
use of its products, including damage or injury caused to other products, machinery, buildings, or property. Watson-
Marlow shall not be liable for consequential damages, including without limitation, lost profits, loss of time,
inconvenience, loss of product pumped, and loss of production.
This warranty does not obligate Watson-Marlow to bear any costs of removal, installation, transportation, or other
charges which may arise in connection with a warranty claim.
Watson-Marlow shall not be responsible for shipping damage of returned items.

3.0.1

Conditions

o

Products must be returned by pre-arrangement to Watson-Marlow, or a Watson-Marlow approved service centre.

o

All repairs or modifications must have been made by Watson-Marlow Ltd, or a Watson-Marlow approved service

centre or with the express permission in writing of Watson-Marlow, signed by a manager or director of Watson-

Marlow.

o

Any remote control or system connections must be made in accordance to Watson-Marlow recommendations.

o

All PROFIBUS systems must be installed or certified by a PROFIBUS approved installation engineer.

3.0.2

Exceptions

l

Consumable items including tubing and pumping elements are excluded.

l

Pumphead rollers are excluded.

l

Repairs or service necessitated by normal wear and tear or by lack of reasonable and proper maintenance are

excluded.

l

Products which, in the judgement of Watson-Marlow, have been abused, misused, or subject to malicious or

accidental damage or neglect are excluded.

l

Failure caused by electrical surge is excluded.

l

Failure caused by incorrect or sub-standard system wiring is excluded.

l

Damage by chemical attack is excluded.

l

Ancillaries such as leak detectors are excluded.

l

Failure caused by UV light or direct sunlight.

l

Any attempt to disassemble a Watson-Marlow product will invalidate the product warranty.

Watson-Marlow reserves the right to amend these terms and conditions at any time.

Содержание 500 Series

Страница 1: ...m 505ca en 01 1 505CA pumphead user manual...

Страница 2: ...erating procedures 9 7 Pumphead installation 10 8 Fitting an extension pumphead 11 9 CA cassette loading 12 10 CA cassette removal 13 11 CA cassette adjustment and flow rates 14 12 Care and maintenanc...

Страница 3: ...2 Certification Certification documents follow on the next pages m 505ca en 01 3...

Страница 4: ...easoned request by the appropriate national authorities relevant information on the partly completed equipment identified above The method of transmission shall be by mail or email 7 The pumphead is i...

Страница 5: ...nd Electronic Equipment Regulations 2012 5 We undertake to transmit in response to a reasoned request by the appropriate national authorities relevant information on the partly completed equipment ide...

Страница 6: ...nience loss of product pumped and loss of production This warranty does not obligate Watson Marlow to bear any costs of removal installation transportation or other charges which may arise in connecti...

Страница 7: ...tion we will issue a Returns Authorisation Number We reserve the right to quarantine or refuse any equipment that is not displaying a Returns Authorisation Number Please complete a separate decontamin...

Страница 8: ...itably trained personnel after they have read and understood this manual and considered any hazard involved Any person who is involved in the installation or maintenance of this equipment should be fu...

Страница 9: ...e pumping element DO fit an extra length of pumphead tube in the system to enable tube transfer This will extend tube life and minimise the downtime of the pumping circuit DO keep the track and roller...

Страница 10: ...eaded screws provided 2 l Apply grease to the drive tongue 1 align to pumphead centre shaft and locate together l Remove the planetary gear system cover by pulling gently towards the front of the pump...

Страница 11: ...lanetary gear system cover from the extension pumphead l Fit the extension pumphead onto the two locating pins ensuring the tongue of its drive shaft aligns with the pumphead centre shaft l Tighten th...

Страница 12: ...stretching it 1 l Lift the cassette release lever 2 l Load the cassettes into the pumphead ensuring that they are engages on the to the cassette guides at each end 3 l Ensure that both retaining clips...

Страница 13: ...a single cassette can be removed for tube changing without stopping the drive and disturbing the pumping action of other cassettes All cassettes must be in position in the pumphead during normal runni...

Страница 14: ...n designed so that when the indicator is at the centre position it is indicating the normal set up l To adjust pull out the adjusting knob and turn To lock push back l Moving the indicator towards the...

Страница 15: ...settes from the pumphead and remove the tubing Wash the cassettes in water and mild detergent If fluid has been spilled into the pumphead removal of the pumphead from the drive will make cleaning easi...

Страница 16: ...ler 4 way Roller 8 way Roller 12 way Roller 16 way 4a BB 0038 2 off Center shaft bearing 4b BB 0014 2 off Center spacer bearing 5 DE 0429T Center gear 6 MN 0983M Roller gear 7 OS 0047 Friction O ring...

Страница 17: ...14 Dimensions Table 2 Dimensions Pumphead channels Dimension X 4 99 8 148 12 197 16 246 Figure 5 Dimensions m 505ca en 01 17...

Страница 18: ...18 m 505ca en 01 15 Publication history m 505ca en 01 First published 12 22...

Страница 19: ...s Figure 1 Pumphead installation 10 Figure 2 Extension pumphead installation 11 Figure 3 CA cassette loading 12 Figure 4 Pumphead spares 16 Figure 5 Dimensions 17 16 2 Tables Table 1 Pumphead spares 1...