CLS200 Series User’s Guide
Chapter 3: Using CLS200
53
ALARM
Control Status
Heat Output
Cool Output
Engineering Units
Process Variable
Setpoint
Loop Number
or Name
Percentage
Percentage
02
160˚F 0
180HEAT100
Figure 3.5
— Single Loop Display, Heat and Cool Outputs Enabled
Navigating the Single Loop Display
In the single loop display:
• Press
YES
to go to the next loop.
• Press
NO
to go to the previous loop.
• Press
BACK
once to go to the job display (if enabled) or bar graph display.
• Press
ENTER
twice to start the single loop scanning display. The single loop scanning display
shows information for each loop in sequence. Data for each loop displays for one second.
• Press any key to stop scanning.
Alarm Displays
If a process, deviation, failed or system sensor alarm occurs, the controller switches from any Single
Loop display or Bar Graph display to the Single Loop display for the loop with the alarm. The global
alarm output turns on and a two-character alarm code appears in the lower left corner of the Single
Loop display.
If the alarm is for a failed sensor, a short message appears in place of the process variable and units.
Control outputs associated with failed sensors are set to the value of the
SENSOR FAIL HT/CL
OUTPUT
%
parameter (default, 0%).
The alarm code blinks and displays cannot be changed until the alarm has been acknowledged.
Once the alarm is acknowledged, the alarm code stops blinking. When the condition that caused the
alarm is corrected, the alarm messages disappear.
ALARM
Alarm Code
Loop Number
180
°F
180AUTO
02
LP
Figure 3.6
— Single Loop Display with a Process Alarm