![Watlow CLS200 Скачать руководство пользователя страница 164](http://html1.mh-extra.com/html/watlow/cls200/cls200_user-manual_3708024164.webp)
CLS200 Series User’s Guide
Chapter 10: Specifications
164
1.00 in.
(25 mm)
1.98 in.
(50 mm)
9.00 in.
(229 mm)
2.44 in.
(62 mm)
Figure 10.3
— CLS200 Clearances with Right-Angle SCSI Cable
Table 10.6
—
Processor Connections
Power Terminals (TB2)
Captive screw cage clamp
Power Wire Gauge (TB2
22 to 18 AWG (0.5 to 0.75 mm
2
)
Power Terminal Torque (TB2)
4.4 to 5.3 in-lb. (0.5 to 0.6Nm)
Sensor Terminals (TB1)
Captive screw cage clamp
Sensor Wire Gauge (TB1)
Thermocouples: 20 AWG (0.5 mm
2
)
Linear: 22 to 20 AWG (0.5 mm
2
)
Communications: 24 AWG (0.2 mm
2
)
Sensor Terminal Torque (TB1)
4.4 to 5.3 in-lb. (0.5 to 0.6Nm)
Output Terminals (TB18)
Captive screw cage clamp
Output Wire Gauge (TB18)
Multiconductor cables: 24 AWG (0.2 mm
2
)
Single-wire: 22 to 18 AWG (0.5 to 0.75 mm
2
)
Output Terminal Torque (TB18)
4.4 to 5.3 in-lb. (0.5 to 0.6Nm)
SCSI Connector
SCSI-2 female
TB50 Physical Specifications
Table 10.7
—
TB50 Physical Dimensions
Weight
0.32 lbs
0.15kg
Length*
4.1 inches
104 mm
Width
4.0 inches
102 mm
Height DIN Rail Mounted
1.5 inches
37 mm
Height Off Panel
(DIN Brackets Removed)
0.92 Inches
23 mm