Active if Output 4 is equipped for
a relay (97 _ _-_ _ _ D-_ _ _ _),
Output 4 (Output 4 Menu) is
set to
[``AL]
(Alarm) and
Setup Page Lock (Lockout
Menu) is not set to
[hide]
.
none*
[both]
[both]
both
[hi``]
high
[lo``]
low
[Sid4]
Alarm Active Sides
4
Selects alarm 4 side
option.
Active if Output 4 is equipped for
a relay (97 _ _-_ _ _ D -_ _ _ _),
Output 4 (Output 4 Menu) is
set to
[``AL]
(Alarm) and
Setup Page Lock (Lockout
Menu) is not set to
[hide]
.
none*
[``no]
[``no]
no action
[`yes]
silence 4
enabled
[SiL4]
Silencing 4
Enables Silence 4.
Active if Output 4 is equipped for
a relay (97 _ _-_ _ _ D-_ _ _ _),
Output 4 (Output 4 Menu) is
set to
[``AL]
(Alarm) and
Setup Page Lock (Lockout
Menu) is not set to
[hide]
.
none*
[``no]
[``no]
no action
[`Yes]
latching
enabled
[Lat4]
Latching 4
Enables alarm 4
latching.
Active if Output 4 is equipped for
a relay, (97 _ _-_ _ _ D -_ _ _ _ ,
Output 4 (Output 4 Menu) is
set to
[``AL]
(Alarm) and
Setup Page Lock (Lockout
Menu) is not set to
[hide]
.
none*
3
1 to 9999
[hys4]
Alarm Hysteresis 4
Sets the switching
hysteresis for the
alarm output. This
defines a band on
the inside of the
alarm set point.
When the process
temperature is in
this band, the alarm
state will not
change.
Active if Output 4 is equipped for
a relay (97 _ _-_ _ _ D-_ _ _ _)
and Setup Page Lock (Lockout
Menu) is not set to
[hide]
.
none*
[`OFF]
[`OFF]
off
[``AL]
alarm
[Ot`4]
Output 4
Selects output 4
type.
[Out4]
Output 4 Menu
[`set]
Setup Page
Active if Output 3 hardware is
present (97 _ _-_ _ D _-_ _ _ _),
Output 3 (Output 3 Menu) is
set to
[``AL]
(Alarm) and
Setup Page Lock (Lockout
Menu) is not set to
[hide]
.
742 r/w
[`Yes]
[``no]
no (0)
[`Yes]
yes (1)
[Anu3]
Alarm
Annunciation 3
Selects alarm 3
annunciation option.
NOTE: For more information about how parameter settings affect the controller’s operation, see Chapter Five, Features.
6 . 1 2
■
P a r a m e t e r s
Wa t l o w S e r i e s 9 7
Setup Page / Output 4 Menu
Display
Parameter
Range
Default
Modbus
Conditions for
Address
Parameters to Appear
read/write
*Output 4 parameters cannot
be changed with the Modbus
interface.