![Watkiss DigiVAC Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/watkiss/digivac/digivac_service-manual_3694152083.webp)
Electronics & Software
•
PCBs
Watkiss DigiVAC Service Manual - Issue 2 - 29/11/04
77
4.2.4 900-140b DigiVAC Standard (Eco-Vario) Control Panel PCB
Dual In Line (DIL) Switches:
The table below shows the functions of the
DIL switches on the DigiVAC Standard Control PCB. The switches have two
positions, ON (towards the PCB) and OFF (away from the PCB). The default
position for the DIL switches is all OFF.
DESCRIPTION
LED
LED FUNCTION (LED ON)
Connection from PL4 on 900-176 DigiVAC Base PCB to:
PL1
Main Power and Communica-
tions
PL2
Data Bus to Feed Bins, including
the
Input Signal from Tacho
LED12
LED9
Trigger Signal to Feed Bins
(flashes each feed)
Tachometer sensor
PL3
unused
PL4
Rear Door Guard Switch Input
LED10
LED11
Rear Door / Guard Switch
closed
always ON
PL5
Beeper Output Connector
IC3
Software EPROM
SW4
Engineering Mode Control
Switch
LED4
Currently in Engineering Mode
DILSW SW 1
SW 2
SW 3
SW 4
Supply Fre-
quency
Input on OSC
BASE SK1
Out mode on
PL4 Base PCB
Input mode PL5
Base PCB
OFF
50Hz
STACK FULL
ERROR SIGNAL
REMOTE STOP
ON
60Hz
Input as PL5
RUN SIGNAL
WAIT
Default = all OFF