5 - Error Conditions, Problems and Solutions - Clear a Stitch Head Jam
Watkiss PowerSquare™200 User Manual
49
Clear a Stitch Head Jam
Problem:
A loud and repeated banging noise from the fold area of the
PowerSquare or the PowerSquare will not start.
Action:
Press the stop button
. The banging noise does not indicate dam-
age has occurred, but can cause alarm. Follow the procedure below.
Tools and Materials:
• Klüber Isoflex NBU15 Grease, 50g. Part number 951-095
• Air duster. Supplied with the machine.
• Wire cutters. Supplied with the machine.
• Flat blade screwdriver
Stitch head
Wire-holder
Wire-holder retaining spring
FIGURE 23. Remove the stitch head wire-holder
FIGURE 24. Inspect for stitch-wire
Inspect this area for pieces of stitch-wire.