Cover
Figure E
Boiler Tank
Power Cord
Fan Cord
Fan Cord Receptacle
7
USING THE COUNTERTOP DISTILLER
1. Set Distiller on a dry, level, well-supported, stable surface.
2. Unplug fan cord from fan cord receptacle. Remove cover and set
aside (fig. E).
3. Fill stainless steel tank to “FULL” line with approximately 1 gallon
(3.8 liters) ordinary tap water. DO NOT OVERFILL (fig. F).
To avoid risk of spilling, use a pitcher to fill the boiler tank.
4. Be sure filter cup is locked in place (fig. D).
5. Replace cover on boiler tank and plug fan cord into receptacle.
6. Remove adapter cover from collection/storage bottle lid and align
opening under filter cup (fig. B).
7. Plug power cord into a properly rated, grounded outlet.
8. Press reset button to turn on Distiller. Red indicator will light and
fan motor will start (fig. B).
9. After about 30 minutes, distilled water will begin to fill collection/
storage bottle. When cycle is complete (approximately four hours for
1 gallon), Distiller turns off automatically. Wait at least 30 minutes
before lifting or removing cover!
WARNING: NEVER LIFT COVER WHILE FAN IS RUNNING.
DO NOT CHANGE POSITION OR LOCATION OF DISTILLER
WHILE IT IS OPERATING OR COOLING. WAIT AT LEAST FIVE
HOURS IF CYCLE IS INTERRUPTED BEFORE MOVING DIS-
TILLER. SEVERE BURNS CAN RESULT FROM HOT, BOILING
WATER OR STEAM.