background image

MAIN DRAIN OWNER’S MANUAL

WARNING - SUCTION ENTRAPMENT HAZARD

Suction in suction outlets and/or suction outlet 
covers which are damaged, broken, cracked, 
missing, or unsecured can cause severe injury and/
or death due to the following entrapment hazards:

Hair Entrapment:

  Hair can become entangled in suction outlet cover.

Limb Entrapment:

  A limb inserted into an opening of a suction outlet 

sump or suction outlet cover that is damaged, broken, cracked, missing, 
or not securely attached can result in a mechanical bind or swelling of 
the limb.

Body Suction Entrapment:

  A negative pressure applied to a large 

portion of the body or limbs can result in an entrapment.

Evisceration / Disembowelment Entrapment:

  A negative pressure 

applied directly to the intestines through an unprotected suction 
outlet sump or suction outlet cover which is damaged, broken, cracked, 
missing, or unsecured can result in evisceration / disembowelment 
entrapment.

Mechanical Entrapment:

  There is potential for jewelry, swimsuit, 

hair decorations, finger, toe, or knuckle to be caught in an opening of a 
suction outlet cover resulting in mechanical entrapment.

USE ONLY GENUINE WATERWAY REPLACEMENT PARTS.

IMPORTANT SAFETY INSTRUCTIONS

Model Number: 640-19xx V    10”  Tru Flo

810-5300.0221

©2021 Waterway Plastics

2200 East Sturgis Road, Oxnard CA 93030 • Phone 805.981.0262 • Fax 805.981.9403

www.waterwayplastics.com • [email protected]

Designed,

Engineered & 

Manufactured 

in the USA.

Read and follow all instructions in this owner’s manual and on the equipment. Failure to follow instructions can cause 

severe injury and/or death.

WARNING:

VGBA

2017

IMPORTANT SAFETY INSTRUCTIONS. READ, UNDERSTAND, AND FOLLOW ALL WARNINGS  

AND INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

SOFA INSTRUCTIONS

When installing and using this equipment, basic safety precautions shall always be followed, including the following: IMPORTANT 

SAFETY INSTRUCTIONS. READ, FOLLOW, AND UNDERSTAND ALL INSTRUCTIONS AND WARNINGS.

Any modification that increases the flow rate of the circulation system shall require re-evaluation of the cover/grate and sump to 

ensure that the flow rating of the Suction Outlet Fitting Assembly (SOFA) is not exceeded.

Missing, broken, or cracked cover/grates, sumps, mud-frames, or any other SOFA component shall be replaced before bathers are 

allowed to use the pool.

Loose cover/grates shall be reattached before bathers are allowed to use the pool.

SAVE THESE INSTRUCTIONS.

Содержание Tru Flo 640-19 V Series

Страница 1: ...al entrapment USE ONLY GENUINE WATERWAY REPLACEMENT PARTS IMPORTANT SAFETY INSTRUCTIONS Model Number 640 19xxV 10 Tru Flo 810 5300 0221 2021 Waterway Plastics 2200 East Sturgis Road Oxnard CA 93030 Ph...

Страница 2: ...seTORX wrench and screw driver for service and removal of fasteners Observe cover grate fasteners for damage each operational day During installation ensure components and fastener receptacles are cle...

Страница 3: ...erization using a Phillips head screw driver remove the screws Inspect both the suction cover and suction fitting for any cracks or damages Any and all broken or missing parts must be replaced prior t...

Страница 4: ...s VINYL LINER ASSEMBLY 1 Install rubber gasket to body by pushing in raised alignment cups into slots in body see Diagram A 2 Lay vinyl liner over main drain 3 Put fiber gasket and mounting plate on t...

Страница 5: ...be used 819 00801 642 3120 642 2410 V 1 2 3 ITEM NO QTY PART NUMBER Description VENDOR Material 3 1 642 3120 10 DRAIN COVER ADAPTER EXTENDED PVC Rigid 2 1 642 2410 V 10 TRU FLOW DRAIN COVER 2011 WATER...

Страница 6: ...00 350 400 450 500 Head In Hg Flow Rate GPM 10 TRU FLOW Head Loss Curve WARRANTY For product registration visit www waterwayplastics com For Warranty questions or claims please contact point of purcha...

Страница 7: ...TER MUD RING PART NO 642 3110 642 2410 V 3 PIPE 3 PIPE FIELD BUILT SUMP POOL STRUCTURE FINISH SURFACE OF THE POOL 9 FLOW PATH 5 FLOW PATH Pipe Size 3 Minimum Sump Depth 9 Minimum Ledge Depth 0 5 Maxim...

Страница 8: ...B B SECTION B B 9 FLOW PATH 3 SOC 3 SOC 5 FLOW PATH FLOW PATH FINISH SURFACE OF THE POOL 810 5300 0221 2021 Waterway Plastics...

Отзывы: