Waterway SMF-115 Скачать руководство пользователя страница 1

SMF PUMP OWNER’S MANUAL

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS • SAVE THESE INSTRUCTIONS

WARNING: Before installing this product, read and follow all warning notices and instructions accompanying this 
pump. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage.

ATTENTION INSTALLER: This manual contains important information about the installation, operation, and safe 
use of this product. This information should be given to the owner/operator of this equipment.

NOTE: When pump is mounted permanently within 5 ft. of the inside walls of a swimming pool, you must use 
No. 8 AWG or larger conductor to connect to bonding conductor lug.

WARNING: To reduce the risk of injury, do not permit children to use this product unless they are closely 
supervised at all times.

CAUTION: For hot tubs and spas, do not install within an outer enclosure or beneath the skirt of a hot tub or spa 
unless so marked.

2200 East Sturgis Road, Oxnard, CA  93030 • Phone 805.981.0262 • Fax 805.981.9403

www.waterwayplastics.com • [email protected]

810-0226.0315

©2015   Waterway Plastics

Designed, 

Engineered & 

Manufactured 

in the USA.

Содержание SMF-115

Страница 1: ...given to the owner operator of this equipment NOTE When pump is mounted permanently within 5 ft of the inside walls of a swimming pool you must use No 8 AWG or larger conductor to connect to bonding...

Страница 2: ...ted to the terminal board 5 Make sure all electrical connections are clean and tight 6 Permanently ground the motor using the internal green ground terminal located on the inside of the motor canopy o...

Страница 3: ...g the pump may cause serious personal injury In order to avoid the possibility of personal injury make sure the suction and discharge valves are open and strainer pot temperature is cool to touch then...

Страница 4: ...operating Do not allow the pump to operate if it has been flooded 5 If a motor has been damaged by water it voids the motor warranty NOTE DO NOT wrap motor with plastic or other air tight materials Th...

Страница 5: ...on a flat surface and tap out the carbon spring seal 11 Clean the seal plate seal housing and motor shaft 1 When installing the replacement ceramic carbon seal use silicone sealant on the metal portio...

Страница 6: ...hil Pan Head Left Hand 1 4 20 X 1 13 310 7470 1 Diffuser Assy 14 819 0018 2 4 40 Uncs Bolt Schs 15 805 0238 1 0 Ring 238 SMF PUMP REPLACEMENT PARTS Part No Qty Description 16 319 1420 1 Diffuser Plate...

Страница 7: ...to run dry resulting in a damaged seal FAILURE OF PUMP 1 Pump will not prime too much air Remedy a Check suction piping and valve glands on all suction gate valves b Secure lid on pump strainer pot a...

Отзывы: