52
|
56
CMCGV/CMUCGV—Building the Isolation Valve Controls
Use the illustration and instructions to build the
installer-supplied manual control components for
the isolation valve.
Note:
Certain parts have been removed from the
illustration to provide a clear view of the
equipment being discussed.
1 Design and build a control panel for the
isolation valve that has the following features:
•
A handle that opens the valve when pulled,
closes the valve when pushed, and locks the
valve in place when twisted.
•
A label indicating the function of the handle.
•
Optional: an LED that illuminates when the
valve is not fully opened or fully closed.
2 Create a control rod to install between the
control panel and isolation valve rack.
3 Use locally sourced hardware and U-joints to
install the control components.
4 If the control panel has an LED, connect the
wiring from the control panel to the appropriate
source.
1