Installing the Transmission Drain Lines—CMC22/CMUC22
Use the illustration and instructions to install the
transmission drain lines. Fluid that is susceptible to
freezing must be drained from the transmission to
prevent damage.
NOTICE
• Do not allow fluid in the
lines to freeze.
• Remove all freezable fluid
from the lines before
storing the apparatus.
Freeze Damage
1 Locate the drain port on the tee fitting.
2 Remove the drain plug.
3 Install the appropriate fittings and hoses to
drain the transmission as required.
2
1