19
|
56
Transfer Valve Actuator Control Panel—Electric Version
TRANSFER VALVE
PRESSURE
VOLUME
Feature
Feature
Description
Description
1 Mounting holes
These are used to mount the actuator control panel to the apparatus.
2
Pressure
button
This button moves the valve into the pressure position.
3
Volume
button
This button moves the valve into the volume position.
4 Connector
This connects to the extension cable that goes between the control panel and encoder—DT06-4S.
5 Bare lead—black
This connects to ground.
6 Bare lead—red
This connects to 12 V.
7 Connector
This connects to the power relay module—DT06-4S.
4
5
6
7
1
2
3