SS-TH500 - 1/2” MINIATURE THERMOSTATIC VALVE 

Features:  

 

Ability to pre-select water temperature – thus conserving water 

 

Compensates for water pressure fluctuations preventing scalding 

 

Safety button at 100°F prevents accidental scalding 

 

High flow rates allow for multiple shower applications 

 

Listed by NSF 

 

Specifications: 

o

 

Operating pressure is 20 PSI to 85 PSI 

o

 

When pressure is higher than 85 PSI a pressure reducer (fitted before the valve) is required. 

o

 

Temperature range is 60°F to 115°F 

o

 

Recommended setting is 45 PSI and 150°F 

 

Note:  

 

DO NOT USE PLUMBER’S PUTTY ON ANY OF THE BRASS COMPONENTS 
This will cause the finish to tarnish and void the warranty. A non-corrosive Alkoxy Silicone is 
recommended. 

 

DURING SWEATING OF LINES DO NOT OVERHEAT CASTING 
Overheating may cause damage to internal mechanism and void the manufacturer’s warranty as 
well as increase the risk of scalding. 

 

COPPER ADAPTORS MAY BE REQUIRED TO COMPLETE YOUR INSTALLATION 

 

  Shipping weight (lbs.): 4  

  Shipping dimension (in.): 6 x 5 x 4.5 

 

Note:  

 

Separate wall stops/shut off valves/volume controls (SS-TS150 or SS-TS200) may be needed in 
conjunction with this valve. A thermostatic valve’s only function is to mix temperature. 

 

Diagram 1: Flow Rate Vs. Pressure 

 

 

Rev. 9/17 

Содержание SS-TH500

Страница 1: ...15 F o Recommended setting is 45 PSI and 150 F Note DO NOT USE PLUMBER S PUTTY ON ANY OF THE BRASS COMPONENTS This will cause the finish to tarnish and void the warranty A non corrosive Alkoxy Silicone is recommended DURING SWEATING OF LINES DO NOT OVERHEAT CASTING Overheating may cause damage to internal mechanism and void the manufacturer s warranty as well as increase the risk of scalding COPPE...

Страница 2: ...ard 5 Connect the outlet pipe Install tile stops volume controls between the thermostatic valve and each device to be operated See Diagram 8 for sample installations Trim Installation see Diagram 4 1 Screw Temperature Control Dome 1 onto valve 2 Slide the Thermostatic Face Plate 3 onto the valve by sliding over the Temperature Control Dome 1 and hold in place 3 Screw Thermostatic Face Plate Lock R...

Страница 3: ...pressures Depending on your preferred hot water temperature setting it may be necessary to adjust the calibrations of the valve The limit override button is preset at 100 F and can be adjusted as described below 1 Select 100 F on the control handle 2 Without turning the handle remove the handle by unscrewing the screw and pulling off screw may be concealed and or fastened with set screws 3 Use a t...

Страница 4: ...nd gently pull out Cartridge 2 5 Clean the screens and rinse with water If necessary soak in a 50 50 mix of white vinegar water or a de scaling agent until all dirt is dissolved Grease the o rings with a silicone based grease and wipe the housing with a wet cloth before reassembling 6 Reassemble the valve by reversing these instructions Make sure the red dot on the temperature limit stop ring and ...

Страница 5: ...on handle is different than actual water temperature Debris in check valves Valve not properly calibrated Uneven hot cold water pressure Remove and clean check valves Calibrate valve following instructions on previous page Check and adjust water pressure for both hot cold supply lines Handle does not turn Mineral build up Remove and clean cartridge following instructions above Low water pressure L...

Страница 6: ...INSTALLTION FOR MINIATURE THERMOSTATIC VALVE Miniature Thermostatic Valve P a g e 6 Diagram 7 Diagram 8 Sample Layouts ...

Отзывы: