background image

Page | 4 

Owner’s Manual

 

Main Display 

 
 

1.

 

Outputs 

Displays active and Inactive. In the picture above Outputs 1 is Active (shaded) and Output 2 
is inactive. Depending on the number of outputs connected to the panel, the display will 
change.  When an output is active, the timer counts down how long until it is deactivated.  
When the output is inactive, the timer counts down how long until it is activated. 

2.

 

Inputs 

Displays whether Inputs 1 to 4 are active. Shaded Inputs are active. 

3.

 

Current Readings 

The current draw in amperage of an active output is displayed here.  For panels with more 
than 5 outputs, current sense will be displayed on a separate screen. 

4.

 

Cellular Connection 

Connection to the server is displayed on the screen by a cell tower icon. 

5.

 

Cellular Signal Strength 

The strength of the cell signal is displayed here. Panel automatically determines best carrier 
to use based on signal strength.   

6.

 

Date / Time 

The date is displayed in DD.MM.YY format. 

7.

 

Time 

The user can select a 12 HR or 24 HR clock in the Date / Time menu. 

8.

 

Interface Buttons 

Keys to navigate around the control panel interface     

 

Key 

Description 

 

Confirm selection 

 

Cancel selection / Go back to previous screen 

 

Scroll Down / Decrease number 

 

Scroll Up / Increase number 

 

Right / Shift character to Right 

 

Left / Shift character to Left 

Содержание Smart Panel

Страница 1: ...stems 2019 Smart Panel Owner s Manual Waterloo Biofilter Systems Inc 143 Dennis Street PO Box 400 Rockwood ON N0B 2K0 Tel 519 856 0757 Fax 519 856 0759 1 866 366 4329 info waterloo biofilter com www w...

Страница 2: ...Page 2 Owner s Manual Table of Contents Table of Contents 2 Alarms 3 Main Display 4 Customer Menu 5 How to Perform Function Test 6 How to use Manual Mode 7 Check Active Inputs 8...

Страница 3: ...ndicates that the water level in the pump tank or Biofilter is too high What should you do You should call your maintenance provider immediately Limit water use until the problem has been corrected Ho...

Страница 4: ...splayed here For panels with more than 5 outputs current sense will be displayed on a separate screen 4 Cellular Connection Connection to the server is displayed on the screen by a cell tower icon 5 C...

Страница 5: ...operation and amperage readings The cycle will run through all enabled outputs by sequence test the alarm and check the backup battery status Manual Mode Allows operator s to temporarily run a specifi...

Страница 6: ...nd Press OK Scroll down to Start Test and press OK A pre set delay will start counting down and the first Active output will turn ON The output will turn ON for the duration of the predetermine cycle...

Страница 7: ...wn to Manual Mode and Press OK In the Manual Mode menu scroll down to the Output you would like to control Press OK to select Choose between Automatic Always ON and Always OFF modes by scroll UP or Do...

Страница 8: ...the bottom of the screen Inputs display whether Inputs 1 to 4 are active Shaded Inputs are active If there are more than 4 inputs in the control Panel the input screen needs to be accessed to verify t...

Отзывы: